1OM-1610
2-18
4. Exiting from the System Program : Chap.2
0911-001
4.3 Locking the Power Breaker
Notice
When the machine is not to be used for a long period of time, lock the
power breaker with the padlock.
Procedure
(1) Pull out the lock lever of the power breaker in Direction A (indicated in the
gure below).
Be sure not to release your hand from the lock lever. Otherwise, the lock
lever will pull back in place.
(2) Engage the shackle of the padlock through the lock slot and lock the crank.
A
Lock Lever
Lock Lever
Padlock
Locking the Power Breaker
F1B13
CAUTION
The padlock key should be kept in such a way that
nobody except the personnel in charge of maintenance can
supervise it.
1OM-1610
0911-001 3-A
Chapter 3
Outline of Automatic Operation
This chapter describes the procedures of daily automatic operations and
component replenishment.
1. Automatic Operation
2. Component Replenishment
3. PCB Replenishment
4. Stop, Interruption, and Restart of Operation
5. Running-In Operation
Chapter 3 Outline of Automatic Operation
1OM-1610
0911-001 3-B