1OM-1626-001_w.pdf - 第122页
1OM-1610 3-3 1. Automatic Operation : Chap.3 091 1-001 1.1.3 ConrmationofCoverSection DANGER There are strong motorized and high-voltage areas inside the machine. Special caution should be paid not to touch them. Do…

1OM-1610
3-2
1. Automatic Operation : Chap.3
0911-001
1.1 Inspections before Automatic Operation
1.1.1 ConrmationofPowerSupply
Conrm that the main breaker of the power supplied to the machine is turned
"ON".
• Power Supply : 200 ± 20 V AC, 3-Phase
• Apparent Power : Approx. 6.1 kVA
1.1.2 ConrmationofAirPressure
Conrm that the air pressure is set to the following.
•
Main Pressure : 0.45 MPa (4.6 kgf/cm
2
)
Note
The above represents the pressure specied while the machine is in
the"STOP" mode.
Min. 0.4 MPa (4.1 kgf/cm
2
) is required while the machine is running.
•
Air Blowing Pressure : 0.05 MPa (0.5 kgf/cm
2
)
Main Pressure
0.45 MPa (4.6 kgf/cm
2
)
Air Blowing Pressure
0.05 MPa (0.5 kgf/cm
2
)
F1C2
Notice
(a) Donotchangethesettingoftheairpressure.Otherwise,the
pneumaticdeviceswillnotworknormally.
(b) Besuretousedryandcleanair.Ifmoisture,oil,dust,etc.,enter
apneumaticdevice(aircylinder,etc.,usedinthismachine),itwill
resultinabreakdownofthemachine.
Note
DryandCleanAir:
Moisture : Dew Point -17°C or less (Atmospheric Pressure)
Oil : 0.1 mg/m or less (ANR)
Dust : Solid 0.01 mm or less

1OM-1610
3-3
1. Automatic Operation : Chap.3
0911-001
1.1.3 ConrmationofCoverSection
DANGER
There are strong motorized and high-voltage areas
inside the machine. Special caution should be paid
not to touch them.
Doing otherwise will cause personal injury (serious
accident).
•
Onlyqualiedmaintenancepersonnelshould
detach the covers.
•
The machine should be operated with the covers
being attached.
•
If a cover is detached, be sure to reattach it.
•
Be sure to close the transparent covers (door type)
before operating the machine.
•
Do not disengage the interlock mechanism of the
transparent covers (door type).
Conrm that the transparent covers above the beams, the safety covers around the
frame, the trans carent covers in the electrical parts storage sections (located under
both ends of and the conveyors) are closed.
Transparent Covers
(Door Type, located over the beams)
Transparent Covers
(Door Type, located over
the beams)
Safety Cover
(locatd around frame)
Safety Cover
(locatd around frame)
Front Side of Machine
Storage Cover of Electrical
Part Storage Box
(located on the lower area
of both conveyor ends)
Cover Lock Switch
(Stage Ready Switch)
F1C3

1OM-1610
3-4
1. Automatic Operation : Chap.3
0911-001
1.1.4 SafetyConrmationofMachineSurroundings
Check the surroundings of the machine and conrm safety before starting the
automatic operation.
CAUTION
Before starting the automatic operation, check
carefully that there is no person around the machine
(especially on the other side of the machine
operation).
Make sure that no objects (tools, parts, etc.) are left
behind.