1.3.3.1 Work during Automatic Operation
ConrmationofOperationModeandProductionLog
The operation mode and the production log can be conrmed in the "Product"
window during the automatic operation.
Under the normal running condition, the current condition such as the program
names, the number of produced PCBs, etc., can be conrmed. In addition to
that, it can also be conrmed how many PCBs can be nished prospectively
and what degree of deterioration in the operation rate can be expected based on
pickup errors, etc.
By using the "Product" window, it can be conrmed if the machine is producing
the PCBs under normal condition or not, if there is any factor to deteriorate
the productivity or not, and what is happening due to the factor and where it is
happening.
When the productivity has deteriorated prominently, it is reported to the
operator with a message issued on the "Product" window.
Replenishment of Components and PCBs
When a component shortage error occurs during the aut
omatic operation, the
machine issues an error alarm. In this case, replenish the component supply.
Reference
Refer to "2. Component Replenishment" for details.
When a PCB shortage error occurs during the automatic operation, the input
machine issues an error alarm or this machine stops running automatically.
Reference
Refer to "3. PCB Replenishment" for details.
Interruption & Restart and Emergency Stop & Restoration of Automatic
Operation
Refer to the following when the automatic operation must be interrupted during
the automatic operation, the machine must be stopped immediately in an
emergency, or the automatic operation must be restarted or restored.
Reference
4.1 Stop of Machine Operation in Chapter 3
4.2 Interruption of Automatic Operation in Chapter 3
1OM-1610
3-12
1. Automatic Operation : Chap.3
0911-001
1.4 End of Automatic Operation
1.4.1 Stop of Automatic Operation
Stop of Automatic Operation by PCB Counter Stop Mode
When the "PCB Counter Stop Mode" function is used, the machine stops
automatically as soon as the counter reaches the specied number of PCBs to
be produced.
Stop of Automatic Operation with [Product STOP] Button
Press the [Product STOP] button in the status indication area (the upper area of
the operation window). The [Product STOP] button turns yellow.
After the machine has placed components on the PCB inside the machine, it
discharges the produced PCB and each device returns to its stationary position.
At this time, the [STAR
T] button on the operation panel extinguishes, the green
lamp of the light tower also goes out, and the automatic operation stops.
[Product STOP] Button
Status Indication Area (Upper Area of Operation Window)
F1C12
Reference
Refer to "4. Stop, Interruption, and Restart of Operation" for the other
ways to
stop the machine.
1OM-1610
3-13
1. Automatic Operation : Chap.3
1.4.2 Logout
When the operation window is closed, press the [Return] button in the common
menu. When the [Return] button is pressed, the operation window is closed and
the "TOP" window is returned.
The "TOP" window opens.
F1C13
Note
(a) Whenever an edit window such as the "Pattern Program Data" window is
active, follow the speci ed steps to close the window before the [Return]
button is pressed.
(b) When the power to the machine is to be turned OFF after the logout, press
the [Shutdown] button.
Refer to "4.2 Interruption of Automatic Operation" in "Chapter 3" for
details.
0911-001