1OM-1610 3-22 3. PCB Replenishment : Chap.3 3.1.2 PCB Manual Removal Procedures Procedure (1) Stop the machine. (2) Remove the PCB from the buffer section. Notice Do not bump the PCB against the transfer PCB detection se…

100%1 / 227
1OM-1610
3-21
3. PCB Replenishment : Chap.3
3. PCB Replenishment
When the machine gets short of PCBs during automatic operation, the input
machine produces an error alarm or the machine stops automatically.
(1) When the input machine has issued an error alarm, follow the step
below.
Replenish the input machine with PCBs and re-start the automatic operation.
(2) When the machine has stopped automatically, follow the step below
The input machine has stopped automatically in a normal condition.
In normal cases, it means that the production is completed.
3.1 PCB Manual Insertion and Removal Procedures
Before the PCB manual insertion or removal operation is performed, pay attention
to the following items.
CAUTION
Before starting the automatic operation, check
carefully that there is no person around the machine
(SIGMA-G4)(especially on the other side of the
machine operation).
Make sure that no objects (tools, parts, etc.) are left
behind.
3.1.1 PCB Manual Insertion Procedures
Procedure
(1) Stop the machine.
(2) Put the PCB on the conveyor belt in the buffer section.
•
When the PCB is to be put on, put the PCB on the belt gently.
Otherwise, the PCB might not be transferred correctly due to conveyer
belt sag or cut out.
Notice
Do not bump the PCB against the transfer PCB detection sensor. Doing
so might damage the sensor, which might disable the normal PCB
transfer.
(3) Press the [START] button on the operation panel to start the PCB transfer.
F1C19
0911-001
1OM-1610
3-22
3. PCB Replenishment : Chap.3
3.1.2 PCB Manual Removal Procedures
Procedure
(1) Stop the machine.
(2) Remove the PCB from the buffer section.
Notice
Do not bump the PCB against the transfer PCB detection sensor. Doing
so might damage the sensor, which might disable the normal PCB
transfer.
0911-001
1OM-1610
3-23
4. Stop, Interruption, and Restart of Operation : Chap.3
4. Stop, Interruption, and Restart of Operation
4.1 Stop of Machine Operation
4.1.1 Temporary Stop (Pause) with [STOP] Button
When you want to check the placement condition after the automatic operation
has been started, press the [STOP] button on the operation panel to temporarily
stop the automatic operation.
Note
(a) When the [START] button is pressed after conrmation of the placement
condition, the automatic operation restarts.
(b) When a wrong pattern program is specied as the current one (production
model), press the [STOP] button to temporarily stop the automatic
operation and follow the instructions described in "4.2 Interruption of
Automatic Operation" to interrupt the automatic operation.
4.1.2 Method based on Stop mode
[Product] Button
[Cycle] Button
F1C20
Stop with [Product] Button
When the [Product] button in the operation window is pressed, the machine
discharges the PCB after the production of the unnished PCB is completed.
After that, the automatic operation stops.
At this time, the green lamps of the [START] button on the operation panel
and the light tower extinguish.
Stop with [Cycle] Button
When the [Cycle] button in the operation window is pressed, the green lamps
of the [START] button on the operation panel and the light tower extinguish
and the automatic operation stops after the machine has placed components
on each PCB of Stages #1 and #2.
0911-001