X/Y Beam Section
This section is equipped with a mechanism by which the placement heads
can be shifted.
By shifting the placement heads in the X and Y directions, the vacuum
nozzles can be attached or detached and some components can be picked and
placed on the PCB.
Automatic Recovery Function
When this function is used and a component shortage error is detected, the
machine is not stopped and a message is issued as machine information,
prompting the operator to replenish components.
The machine continues to place the components other than the missing ones
(component-shortage detected ones). After it has placed all components
(excluding the missing ones), it stops running without discharging the PCB.
When component shortage errors, etc., are detected in different feeders at a
short interval, the loss time can be reduced because the components in short
can be replenished collectively.
Warm Start
When a normal restart operation is performed after the continuous operation
has become impossible during component placement, the PCB in the middle
of process is discharged to the output machine, producing a defective PCB.
In this case, the reset operations must be performed through this "Warm
Start" procedure.
Cover Section
This mechanism works to protect the operator from any danger.
The machine is provided with covers (located over the beams), safety covers
(located around the frame), and storage covers (located on the lower area of
both conveyor ends). The covers and safety covers are prepared to avoid any
danger (to keep an object including part of body and cloths out of the moving
mechanisms inside the machine) during automatic operation.
Inside the storage covers, some electrical parts are stored.
Camera Offset
This offset data is used to adjust the deviations based on the design
dimensions between the positioning reference point (coordinates X
(horizontal), Y (vertical) and Z (theta)) and the center of the camera.
Angle Z is an angle in the PCB positioning and camera coordinates systems.