1OM-1610 3-25 4. Stop, Interruption, and Restart of Operation : Chap.3 4.2 Interruption of Automatic Operation 4.2.1 Interruption with [Cancel] Button When it was found that a wrong pattern program is specied as the cur…

1OM-1610
3-24
4. Stop, Interruption, and Restart of Operation : Chap.3
4.1.3 Method based on Setting of Automatic Operation Stop
Set the "Auto stop mode" to [Enable] in advance on the "PCB Transfer Mode" tab
sheet.
When the operation is the input machine is completed, the machine is
automatically stopped after all the PCBs on the system line are processed and
discharged.
F1C21
Note
If any machine manufactured by any other company is connected in this online
conguration, this function might not be available.
0911-001
Graphic
Development

1OM-1610
3-25
4. Stop, Interruption, and Restart of Operation : Chap.3
4.2 Interruption of Automatic Operation
4.2.1 Interruption with [Cancel] Button
When it was found that a wrong pattern program is specied as the current one
(production model) and the production must be interrupted, follow the steps below
to interrupt the automatic operation.
Procedure
(1) Press the [STOP] button on the operation panel.
The automatic operation stops temporarily.
(2) Press the [Operation] button on the submenu bar of the "Operation" window.
The "OPERATION" window appears.
F1C22
(3) Press the [Cancel] button.
The automatic operation is interrupted.
Note
To continue the automatic operation from this interrupted mode, refer to "4.3
Resumption of Production through Warm Start Procedure" for details.
Notice
When a normal restart operation is performed after the continuous
operation has become impossible during component placement, the PCB
in the middle of process is discharged to the output machine, producing
a defective PCB.
Be sure to perform the reset operations through the "WARM START"
procedure.
0911-001

1OM-1610
3-26
4. Stop, Interruption, and Restart of Operation : Chap.3
4.2.2 Interruption with [EMERGENCY STOP] Switch
To stop the machine immediately in an emergency, press the [EMERGENCY
STOP] switch.
[EMERGENCY STOP] Switches
F1C23
An alarm is issued and the [POWER ON] button illuminates in red.
0911-001