1OM-1626-001_w.pdf - 第65页
1OM-1610 1-8 2. Name and Function of Each Section : Chap.1 091 1-001 Short Appendix : Feeder Ready Switches Switch ON (Short Push) LED OFF (1) S witch Operations and T r ansition of Machine Condition [Ordinary Operations…

1OM-1610
2. Name and Function of Each Section : Chap.1
1-70911-001
2.3 Feeder Ready Switches and Cover Lock Switches
Cover Lock Switches
[Cover READY] Button
(Cover Lock Switches)
Operation Panel
F1A5
2.3.1 Feeder Ready Switches
The feeder ready switches are used to indicate that the feeder bases are set ready
and each switch is employed in each feeder block.
When the "START" button is pressed, the feeder clamp is activated and when the
machine is stopped or paused, the feeder clamp is released.
Also, this function enables the operator to perform operations while checking the
feeder pickup sections.
2.3.2 Cover Lock Switches
The cover lock switch is used to allow the automatic operation and located on the
operation side.
While the LED of the switch is ON, the transparent cover (door type) on the
selected stage cannot be opened because it is locked electromagnetically.
The LED cannot be turned on with the transparent cover kept open.
In addition, no power is supplied to the main circuit of the beam when the LED of
the [Cover Lock] Switches are turned ON.
The main circuit is powered only when the LEDs of both related stage and Feeder
Ready switches are turned ON.

1OM-1610
1-8
2. Name and Function of Each Section : Chap.1
0911-001
Short Appendix : Feeder Ready Switches
Switch ON (Short Push)
LED OFF
(1)
S witch Operations and Tr ansition of Machine Condition
[Ordinary Operations with Machine in "STOP" (or "PAUSE") Mode]
Feeder Ready Switches
Switch Status Machine Status
LED ON
Feeder Clamp Holding Bar :
Locked
Power Supply to Feeders :
:
Switch Status Machine Status
LED OFF
Feeder Base
"Replacement and Setup Operations of Feeder Bank
Lower Limit
Carriage Cart" Possible
Feeder
Clamp Holding Bar :
Unlocked
Power Supply ( 24
V) to Feeders :
Intercepted
Feeder
Attachment/Detachment Operation :
Possible
Power Supply to Connector for
feeder Base Installed on Main Machine
:
Intercepted
Note
During the transition of the machine status along with the above-described
switch operations, the [FEEDER READY] switches flicker, regardless of a
LED lighting pattern such as "ON" to "OFF", "OFF" to "ON", or "OFF" to
"OFF".
Switch ON
(Short Push)
Powered
Locked
Feeder Base Drop Prevention
:
Unlocked
Feeder Base Drop Prevention
Feeder
Attachment/Detachment Operation :
Impossible
LED OFF
"Operation of Feeder Ready" Permitted by Operator

1OM-1610
2. Name and Function of Each Section : Chap.1
1-90911-001
Short Appendix : Cover Lock Switch
Switch ON
LED ON
Switch ON
LED OFF
Cover Lock Switches
Switch Status Machine Status
LED ON
"Operation of Cover Lock" Permitted by Operator
Electromagnetic Locks of
Transparent Covers :
Locked
(Transparent Covers Opening
Impossible)
Switch Status Machine Status
LED OFF
"Operation of Cover Lock" Rejected by Operator
Electromagnetic Locks of
Transparent Covers :
Unlocked
(Transparent Covers Opening /
Closing Possible)