HLGB-10106-01 Origin Return of the Unit (M/C ORG) [Procedure] Check that two plungers are withdrawn. T urn RT axi s to a p osition where inner shaft upper end mat ches H axis pusher . It is unnecessary to raise the alter…

HLGB-10105-01
Calibration Data Load
After loading jig data, check the following description in Calib.ini.
・ Should be same value as MOUNT_HEIGHT in NOZZLE_S_TYPE_G = head.ini.
・ Should be a value obtained by subtracting “3” from MOUNT_HEIGHT in NOZZLE_T_TYPE_G =
head.ini .
・ Should be a value of H of [FixedCamera] POS_XYH in FIXED_INSP_HEIGHT = head.ini.
Press the Use the same jig button.
When performing calibration again, use the
previously used jig wherever possible.
“
Perform calibration sequentially from the
upper on this menu screen.
Any buttons displayed in gray become effective
by completing calibration items on the above.

HLGB-10106-01
Origin Return of the Unit (M/C ORG)
[Procedure]
Check that two plungers are
withdrawn.
Turn RT axis to a position where inner
shaft upper end matches H axis
pusher.
It is unnecessary to raise the alternation carts.
For any malfunction of the unit during origin
return, prepare to immediately press the
emergency stop switch.

HLGB-10106-01
Origin Return of the Unit (M/C ORG)
< Operating sequence of origin return >
Origin return of H/F axis
Origin return of X/Y axis, RT/RN axis
Turn OFF the interlock key when removing the alternation cart after origin return or when opening the
door to perform working.
Since the function of the area sensor is enabled when the interlock key is ON, the unit is in the emergency
stop state if your hand etc is put into the unit.
Similarly, when the alternation cart is removed from the unit with the interlock being ON, the unit is in
the emergency stop.