HLGB-10313-01 Mount A ccuracy Calibration Click the OK button on the confirmation window . Press the [ST ART ] butt on on the operation pane l .

HLGB-10313-01
Mount Accuracy Calibration
Display OPERATION SETUP to check
that settings are as follows.
Display Motion Setup (Unit) screen to
check that settings are as follows.
Make sure the wrong pickup or pickup error
does not occur.
Click in an order of M/C SETUP menu
M/C MAINTENANCE tab
Calibration button.

HLGB-10313-01
Mount Accuracy Calibration
Click the OK button on the
confirmation window.
Press the [START] button on the
operation panel.

HLGB-10313-01
Mount Accuracy Calibration
When the calculation result is 3Sigma <
±40[µm] and Avg < 10[µm], the catalog SPEC
(±60[µm] CPK > 1.0) is satisfied.