MAN00000772_SI-G200BB_SVCPDFA.pdf - 第352页

HLGB-10419-01 Fixed Ca mera Pickup Check Sensor Adjustment Status of the sensor can b e checked even by the I/O monitor . L D Remove all jigs. Install the cool i ng f a n for fixed camer a to the previous position. Insta…

100%1 / 712
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
Turn the SET/RUN selector switch to
SET side.
Check that the sensor adjusting nozzle
(1) is just below the fixed camera jig
nozzle.
Press either one of DOWN or UP
button.
L D
Move the sensor adjusting nozzle (2)
just down to the fixed camera jig
nozzle.
Press either one of DOWN or UP
button.
Turn the SET/RUN selector switch to
RUN side.
L D
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
Status of the sensor can be checked even by the
I/O monitor.
L D
Remove all jigs.
Install the cooling fan for fixed camera to the previous position.
Install the shooter and the lower cover.
HLGB-10420-01
Area Sensor Optical Axis Adjustment
Supply section of cassette specification is different from that of tray specification in optical axis
position of area sensor. Be careful of sensor mounting position and hole position for jig before
carrying out optical axis adjustment.
[Necessary jigs]
Optical axis adjustment jig
[Procedure]