HLGB-10313-01 Mount A ccuracy Calibration

HLGB-10313-01
Mount Accuracy Calibration
Click in an order of
PWB TRANSPORT
tab Conv. Wid. Adj. button.
Click the Abs. Move button.
Input “70” into the input box of the
Conv. Width Abs. Pos.
Press the [START] button on the
operation panel.
Click the Return button to close the
Conv. Adj. screen.
Put glass PWB on glass PWB frame
and hold it with clamp.
Attach double-stick tape on area of the
glass PWB in the figure.
Attach the double-stick tape paying attention to
the position and tape attachment area.

HLGB-10313-01
Mount Accuracy Calibration

HLGB-10313-01
Mount Accuracy Calibration
[Transcription calibration]
“ ”
To execute the calibration for the rear head, select “1005C transCalibrationRear.PW4”.
Click in an order of AUTO menu
STATUS tab … button.
Select the “1005C
TransCalibrationFront.PW4” and click
the Select button.
In the Supply Position field, enter the supply
unit number on which you placed the cassette.
Click the NC Reset button on the
MOTION Setup (Unit) screen.