MAN00000772_SI-G200BB_SVCPDFA.pdf - 第350页

HLGB-10419-01 Fixed Ca mera Pickup Check Sensor Adjustment Servo off only H-axi s . Click in an o rder of M/C SETUP menu  ORG OFFSET tab  Indv . Axis button.  Click the servo OFF button f o r H a xis.   Check wh et …

100%1 / 712
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
Click the Jog Move button.
Press the cursor key and move the
center of the fixed camera jig nozzle to
cross point of the hair lines on the
PARTS DISPLAY screen.
After moving the head, click the
Return button to close the XY Axis
screen.
When performing this operation immediately
after auto calibration, absolute-move the head to
the position described
on#PbPointForFixedCam1 in Calibration.dat
using MANUAL/AXIS MOTION menu to adjust
fine position. More accurate position adjustment
will be possible.
Put “Fixed camera parts presence/absence
sensor adjustment jig“ on “Fixed camera
jig base“.
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
Servo off only H-axis.
Click in an order of M/C SETUP menu
ORG OFFSET tab Indv. Axis
button.
Click the servo OFF button for H axis.
Check whether “Sensor adjusting nozzle
(1) “ is under the “Jig nozzle for fixed
camera“. Fix “Fixed camera parts
presence/absence sensor adjustment
jig“ After check the position of “Sensor
adjusting nozzle (1) “.
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
Turn the SET/RUN selector switch to
SET side.
Check that the sensor adjusting nozzle
(1) is just below the fixed camera jig
nozzle.
Press either one of DOWN or UP
button.
L D
Move the sensor adjusting nozzle (2)
just down to the fixed camera jig
nozzle.
Press either one of DOWN or UP
button.
Turn the SET/RUN selector switch to
RUN side.
L D