HLGB-10203-01 Acquiring Mounting Stro ke Setu p Check the gap between the lengt h reference nozzle jig and cali bration plate jig usi ng t hickness gauge of 0.03mm. After completing to adjust the gap of 0.03mm, press the…

100%1 / 712
HLGB-10203-01
Acquiring Mounting Stroke Setup
Click the XY button on the Acquiring
mounting stroke screen.
XY Axis screen is displayed.
Click the Jog Move button.
Press the cursor key to jog move the
head unit onto the calibration plate
jig.
Click the Return button to return to
the Acquiring mounting stroke screen.
Click the R.H button on the Acquiring
mounting stroke screen.
RN/H Axis screen is displayed.
Click the Jog Move button.
Press the downward cursor key and
lower until the gap between the length
reference nozzle jig and calibration
plate jig becomes 0.03mm.
Slowly lower by Jog slow move while checking
the nozzle position so that the length reference
nozzle jig does not collide he calibration plate
jig.
HLGB-10203-01
Acquiring Mounting Stroke Setup
Check the gap between the length
reference nozzle jig and calibration
plate jig using thickness gauge of
0.03mm.
After completing to adjust the gap of
0.03mm, press the Return button on
the RN/H Axis screen to return to the
Acquiring mounting stroke screen.
Click the Save button on the Acquiring
mounting stroke screen.
< Storing area of calib.ini file >
Record the value of
NOZZLE_S_TYPE_G described in
calib.ini.
< Storing area of calib.ini file >
Click in an order of M/C SETUP menu
MOTION SETUP tab Nozzle tab.
HLGB-10203-01
Acquiring Mounting Stroke Setup
Input a value of 1/1000 of the value
described in calib.ini into the Mount
height.
Example:
Press the Set button.