MAN00000772_SI-G200BB_SVCPDFA.pdf - 第282页

HLGB-10316-01 Measuring Parallelism of Reference Pin and Dependent Pin [Procedure] Press the [ORG] button on t he operation pan el with the HI screen being displayed. Click in an order of MANUAL menu  PWB TRANSPORT tab …

100%1 / 712
HLGB-10315-01
Conveyor Width Adjustment
Click in an order of M/C SETUP menu
CONV. PARAM tab.
Enter a difference value between the
value of narrowest conveyor width
measured in the procedure 3 and the
standard value “410.5 mm” into the
CV offset box.
Click the Set button.
HLGB-10316-01
Measuring Parallelism of Reference
Pin and Dependent Pin
[Procedure]
Press the [ORG] button on the operation panel with the HI screen being displayed.
Click in an order of MANUAL menu
PWB TRANSPORT tab Locator
Pin Up button.
Click in an order of MANUAL menu
VISION tab Check button.
Click in an order of MANUAL menu
AXIS MOTION tab XY button.
HLGB-10316-01
Measuring Parallelism of Reference
Pin and Dependent Pin
Click the Rel. Move button in the
move mode.
Click the X axis and Y axis and put
check mark.
Enter “480” into the box of X axis, and
“260” into the box of Y axis.
Press the [START] button on the
operation panel.
Click the Jog Move button in the move
mode.
Press the cursor key to move XY axes
so that the reference pin is displayed
on the center of the “PCBOARD
DISPLAY” screen.
Click the Return button to close XY
axes screen.
In a state that the reference pin is on
the center of the “PCBOARD
DISPLAY” screen, check the
coordinate value of Y axis on the axis
operation screen, and record the value.