HLGB-10302-01 Fixed Camera Light Calibration Remove the fixed came ra light calibration jig and click the OK button. When subsequently performing calibrati o ns of fixed camera middle light/fixed camera lower light/fixed…

HLGB-10302-01
Fixed Camera Light Calibration
Press the [START] button on the operation panel.

HLGB-10302-01
Fixed Camera Light Calibration
Remove the fixed camera light
calibration jig and click the OK
button.
When subsequently performing calibrations of
fixed camera middle light/fixed camera lower
light/fixed camera coaxial light, it is
unnecessary to remove the jig.

HLGB-10303-01
Light calibration for Global
Recognition
/ / /
Calibration procedure of Top Light for Global Recognition will be described here as an example.
Also perform calibrations of Middle Light for Global Recognition/ Bottom Light for Global
Recognition/ Coaxial Light for Global Recognition by the same procedure.
[Necessary jigs]
• Fixed camera light calibration jig
• Reflection intensity spacer
[Procedure]
Click the Light Calibration button on
the CALIBRATION screen.
Click the Light for Global Recognition
button on the Light Calibration
screen.