MAN00000772_SI-G200BB_SVCPDFA.pdf - 第641页
RPGB-10101-01 F A xis Belt Replacement Procedure

RPGB-10101-01
F Axis Belt Replacement Procedure
[Necessary Jigs]
• Tension meter (UNITTA U-505)
• Tension jig (for G only)
[Removal]

RPGB-10101-01
F Axis Belt Replacement Procedure

RPGB-10101-01
F Axis Belt Replacement Procedure
Remove the U nut with a wrench.
Remove both of two pulley shafts.