MAN00000772_SI-G200BB_SVCPDFA.pdf - 第252页

HLGB-1031 1- 01 Pickup Position Setup Move the pickup point ji g t o the positions of Z120 or Z 139. Click #2 or #3 . Acquire pickup pos i tion d ata of Z120 and Z139 in the same p ro cedure as those in the “XY Positi on…

100%1 / 712
HLGB-10311-01
Pickup Position Setup
[H Position Data Teaching]
Click the H button on the front and
cassette position whole teaching
screen.
Click the Jog Move button.
Press the downward cursor key to
lower the H axis until the gap between
the length reference nozzle jig and
pickup point jig becomes 0.03mm.
Check that thickness gauge of 0.03mm
is inserted into the gap, and thickness
gauge of 0.04mm is not inserted.
Use a thickness gauge with the same
thickness as the “spacer thickness” input in
the Front/All Cass. Pos. Teaching by Tools
screen.
Click the Acq. Pos. button on the H
screen to acquire H position of Z106.
Click the Close button to close H
screen.
Click the Head button to move the
head away from the pickup position.
HLGB-10311-01
Pickup Position Setup
Move the pickup point jig to the
positions of Z120 or Z139.
Click #2 or #3.
Acquire pickup position data of Z120
and Z139 in the same procedure as
those in the “XY Position Data
Teaching” and “H Position Data
Teaching” (procedure 1 to 3).
Click the Calc. button.
Click the OK button.
Click the Return button on the
Front/All Cass. Pos. Teaching by Tools
screen to close the screen.
Check the Set button for the Front
Pos. Data is displayed in blue letter.
Unless the Set button is displayed in blue,
position calculation is not performed. Again,
perform “Acq.Pos.” or “Calc.”.
Click the Set button.
HLGB-10311-01
Pickup Position Setup
Click the Update button.
Check that the front position data
value was updated.