HLGB-10208-01 Pickup Check Camera Setup Click in an ord er of Manual menu V ision tab Check button. Apply a sca l e on the screen to ch eck that lengt h of the displayed jig nozzle end is 3.0mm. For actu al dimension…

HLGB-10208-01
Pickup Check Camera Setup
×
Before tightening cap screws (4-CP2.5×6),
apply small amount of adhesive “1401B” of
THREE BOND to prevent looseness.
[Position adjustment for lowering end stopper]
Click in an order of M/C SETUP menu
ORG OFFSET tab ↓Check
button.
Press the arrow mark on the right
upper section of the screen.

HLGB-10208-01
Pickup Check Camera Setup
Click in an order of Manual
menuVision tab Check button.
Apply a scale on the screen to check
that length of the displayed jig nozzle
end is 3.0mm.
For actual dimension of the nozzle, end of 1mm
is displayed on the screen.
Click in an order of M/C SETUP
menuORG OFFSET tab
↑ Check button to raise the Pickup
check camera.

HLGB-10208-01
Pickup Check Camera Setup
Loosen the locknut for the absorber.
8
7
6
Click the ↓ Check button on the
origin offset screen to lower the Pickup
check camera.
Turn the absorber to adjust the
protrusion amount.
Click the ↑ Check button on the
origin offset screen to raise the Pickup
check camera again.
Tighten the locknut for the absorber.