MAN00000772_SI-G200BB_SVCPDFA.pdf - 第371页
HLGB-10425-01 Adjustment and checking of H-axis soft ware lim it Click the Abs. Move button. Click the H - axis button and input “1.5” into the input space. Press the [ST ART] butto n on the operation panel. Click the OK…

HLGB-10425-01
Adjustment and checking of H-axis
software limit
Open Notepad by the ac_param.ini
file.
Input “1.500” into a space of
“SOFT_LIMIT_PLUS” of [AC_H].
Input “- 26.40” into a space of
“SOFT_LIMIT_MINUS” of [AC_H].
Save the ac_param.ini file and end.
Open the Properties window of the
ac_param.ini file, and check the
“Read-only”.
Close the explorer window.
Press the power off switch.
Press the power on switch.
Click in an order of MANUAL menu
AXIS MOTION tab R.H button.
3.800
1.50
-26.40

HLGB-10425-01
Adjustment and checking of H-axis
software limit
Click the Abs. Move button.
Click the H-axis button and input “1.5”
into the input space.
Press the [START] button on the
operation panel.
Click the OK button.
Input “-26.4” into the input space of
the H-axis in the Abs. Move.
Press the [START] button on the
operation panel.
Click the OK button.
-26.40