HLGB-10420-01 Area Sensor Optical Axis A dj ustment Cassette specification is d ifferent from tray specification in jig hole to be used. Holes on the front are fo r cassette specification and holes o n the back are for t…

100%1 / 712
HLGB-10420-01
Area Sensor Optical Axis Adjustment
Check that the replacing carrier has
been raised.
Set the optical axis adjustment jig on
the cassette table of supply No.101.
There should be no gap between the optical axis
adjustment jig and the cassette table.
Loosen the mounting bolts for the area
sensor to adjust up and downward
positions.
Loosen the cap screw on the lower side
of the bracket to adjust forward and
backward position of the area sensor.
HLGB-10420-01
Area Sensor Optical Axis Adjustment
Cassette specification is different from tray
specification in jig hole to be used.
Holes on the front are for cassette specification
and holes on the back are for tray specification
with the optical axis adjustment jig being placed
on the cassette table.
Remove the optical axis adjustment
jig.
Click in an order of MANUAL menu
I/O tab Serial I/O button
Input tab.
When shielding the area sensor by
hand, check that the sensor is turned
OFF.
HLGB-10421-01
Ejector Setup
[Procedure]
Set four holes on the left side pulley
horizontally/vertically.
Move the pusher by hand so that the
pusher left face is at the ORG position.
Loosen the screws on the mounting
bracket for the ORG sensor.
Tighten the screws on the mounting
bracket to fix on a boundary where the
LED on the ORG sensor changes to
lighting off to lighting up.