HLGB-10310-01
Fixed Camera Rcg Height Calibration
Close the calibration menu screen to return the unit to the origin.
Remove the fixed camera jig base and length reference nozzle jig.
Install the cooling fan for fixed camera to the previous position.
Install the shooter and the lower cover.
HLGB-10311-01
Pickup Position Setup
Pickup position setup can be performed at three locations on the front cassette table (Z106, Z120,
Z139) and at three locations on the rear cassette table (Z106, Z120, Z135).
Perform pickup position setup for tray specification only on the rear side cassette table (Z101, Z108,
Z117).
[Necessary jigs]
Pickup point Jig
Length reference nozzle jig
Thickness gauge
[Preparation before work]
Install the length reference nozzle jig
to the turret No.1.
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is not
drawn out by pulling downward.
Set pickup point jig to Z106 on the
cassette table.
There should be no gap between the feed
adjusting jig and the cassette table.
HLGB-10311-01
Pickup Position Setup
Click in an order of M/C SETUP menu
PARTS SUPPLY tab.
Click the Teaching button on the Front
Pos. Data to display a drop down
menu.
Click the Jigs in the drop down menu.
Click the Tool Setup button.