HLGB-10305-01 Auto Calibration (Recognition of Relationship between th e Fixed Camera and Nozzle) If an error o ccurs and the process aborts, clean the jig chips an d then restart the calibration from Sequence 1. ・

100%1 / 712
HLGB-10305-01
Auto Calibration
(Recognition of
Relationship between the Fixed Camera
and Nozzle)
Click the Recognition of relationship
between AUX camera and nozzle
button on the Multi-functional
machine calibration screen.
Click the Start button of Sequence 1.
Press the [START] button to start the
auto calibration.
In a process of recognizing a large glass PWB,
some portion of PWB may not be recognized.
Even so, keep on the operation.
HLGB-10305-01
Auto Calibration
(Recognition of
Relationship between the Fixed Camera
and Nozzle)
If an error occurs and the process aborts, clean
the jig chips and then restart the calibration
from Sequence 1.
HLGB-10306-01
Auto Calibration (Recognition of
Relationship for the Multiple Recognition)
[Necessary jigs]
Calibration data FD
Calibration plate jig
Positioning pins for calibration plate
BF00900 nozzle (1 pc.)
BF60400 nozzle (7 pcs.)
Calibration jig chip (t=3.4, 1 pc.)
Calibration jig chip (t=1.4, 8 pcs.)
Calibration jig chip (glass)
[Procedure]
When performing recognition of relationship for the Multiple Recognition subsequently from
calibration of position relationship between the fixed camera and nozzle, start operation from the
procedure 6.
Put 8 thinner jig chips (t=1.4mm) to
front side.
Put thicker jig chip (t=3.4mm) to the
right end of the deep row.
Put jig chip (glass) on the right
countersunk section.