HLGB-10202-01 H A xis Origin Position Setup

HLGB-10202-01
H Axis Origin Position Setup
Click the Setup Start button on the H
Axis Home screen.
Press the [START] button on the
operation panel.
Lower the H axis roller by hand and
gradually return it to the top end.
After returning the H axis, push up the inner
shaft from lower section by finger and check
that the inner shaft has returned to the
uppermost end.
Press the [START] button on the
operation panel.
Repeat working of the procedure 2.-4.
up to the turret No.8.

HLGB-10202-01
H Axis Origin Position Setup

HLGB-10203-01
Acquiring Mounting Stroke Setup
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
Calibration plate jig
Jig positioning pin
Length reference nozzle jig
Thickness gauge (t=0.03 mm)
[Procedure]