HLGB-10310-01 Fixed Camera Rcg Height Calibration Carry out working with care not to damage the fiber cable for parts presence/absence detecting sensor . Click in an order of M/C SETUP menu M/C MAINTENANCE tab Calibr…

HLGB-10310-01
Fixed Camera Rcg Height Calibration
[Necessary jigs]
Length reference nozzle jig
Fixed camera jig base
Thickness gauge (t=0.03 mm)
[Procedure]
Loosen screw (2-+T4x8) to remove the
lower cover.
Tile the lower cover slightly toward you and pull
the fan cable to remove the lower panel.
Loosen screw (2-+T4x8) to remove the
shooter.

HLGB-10310-01
Fixed Camera Rcg Height Calibration
Carry out working with care not to damage the
fiber cable for parts presence/absence detecting
sensor.
Click in an order of M/C SETUP menu
M/C MAINTENANCE tab
Calibration button.
Click the Fixed Camera Rcg Height
button on the CALIBRATION screen.
“ ”
Click the Yes button.
“
”

HLGB-10310-01
Fixed Camera Rcg Height Calibration
Press the [START] button on the
operation panel.
Install the length reference nozzle jig
to the turret No.1.
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is not
drawn out by pulling downward.
Press the [ORG] button on the
operation panel.
Press the [START] button on the
operation panel.
Click the Jog Move button.
Press the cursor keys to jog move the
length reference nozzle jig onto the
fixed camera jig base (high level
difference face).
Click the Return button.
If the Shift key on the keyboard is pressed,
Fast/Slow for Jog Move can be switched.