BGA package after reflow . Corner glue prior to reflow (pre- reflow) requires that the BGA package have suf f icient sub- strate available outside of the edge of the last solder ball in the outermost rows (see Figure 7-16).…

Proper fillet height is desirable for maximum underfill per-
formance. The presence of a fillet that extends between
25% and 100% of the way up the side of the package near
its midpoint is considered acceptable in most applications.
Keepout zones for other devices and open vias are required
around the periphery of the BGA being underfilled. A con-
servative rule for keep outs is 1.5X the height of the top of
the substrate of the BGA package from the PCB surface on
the nondispense sides of the package and 6.0 mm on the
dispense side of the BGA package.
Underfills packages are cured in ovens. One desirable
method for curing these boards is using a single pass
through a standard SMT oven run at a lower than reflow
temperature. Many underfill chemistries can be cured in
5-20 minutes at 120-165°C which may be conducive to this
approach. Batch ovens may also be used. Underfill vendors
have been introducing new formulations that cure at lower
temperatures over less time.
Historically, underfill epoxies have not been practically
reworkable in an HVM environment. This was more
acceptable initially in devices such as early generation cell
phones where the cost of each board was relatively low and
scrapping a few boards was not a significant cost penalty.
However, underfill is penetrating more and more high
value markets. As a result, underfill vendors are developing
chemistries that are more reworkable in HVM.
Partial or corner only underfill is done by dispensing
underfill in dot or ‘‘L’’ shaped patterns near the corner of
BGA packages. The underfill flows into a roughly arc
shaped pattern and envelops several solder balls deep at
each corner (see Figure 7-14).
This method has the advantage over full underfill in that
much less underfill material can be used, and also that
underfill flow time can be greatly reduced which can help
increase the production rate associated with the dispense
step. As expected, partial or corner only underfill does not
have quite the strength improvement of fully underfilled
packages; however, in many situations the performance
improvement gained with partial underfill is more than
enough to meet the market requirements for the package/
board being protected. (An experimental case showed a
1.5X increase in shock level where the onset of mechani-
cal damage was sustained for a partial corner underfill
BGA versus the same nonfilled BGA. This is very signifi-
cant.)
Some manufacturers of mobile PC motherboards have used
partial underfill to increase the strength of the BGAs on
their boards.
7.2.2.2 Corner Applied Adhesive Corner applied adhe-
sive (sometimes called corner glue, corner bond or corner
tack) is a method for applying glue only to the corner
and/or outer edges of a BGA package. The theory is that by
re-enforcing the area of the package that is under the most
stress, the solder balls farthest from the center of the pack-
age, package performance can be improved. Corner applied
adhesives do not improve package performance as much as
conventional full capillary flow underfill, but often the
advantage gained is significant and enough to meet market
requirements. The corner glue approach has been widely
adopted by markets that require high mechanical require-
ments (shock, vibration, and bend) on large BGA packages
(20 x 20 mm to 45 x 45 mm). The mobile PC motherboard
market matches this description.
A photograph of a BGA package mounted with corner glue
is shown in Figure 7-15.
Corner glue can be applied either directly to the PCB prior
to BGA package placement and reflow or to the assembled
Figure 7-13 Examples of Underfill Voids - small, medium and large; upper left, lower left and left of solder balls, respectively
Figure 7-14 Example of Partial Underfill - package was
pulled from the PCB and dark underfill can be seen in the
corners
January 2013 IPC-7095C
89
Copyright IPC-Association Connecting Electronics Industries
Provided by IHS under license with IPC
Not for Resale
No reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---

BGA package after reflow. Corner glue prior to reflow (pre-
reflow) requires that the BGA package have sufficient sub-
strate available outside of the edge of the last solder ball in
the outermost rows (see Figure 7-16).
The minimum width of available substrate where pre-flow
corner glue can be applied is approximately 0.7 mm. With
packages with less than this amount of substrate available,
this process is not controllable in HVM. Current trends are
that package substrate sizes are shrinking and the use of
pre-reflow applied corner glue is expected to drop off.
The effectiveness of corner glue post assembly and reflow
methods depends on the type of glue chosen and the total
surface area contacted at each corner. Dispensed amounts
vary from essentially single glue dots at each corner to ‘‘L’’
shaped brackets of glue that extend down the side of the
package by up to six solder balls on each side of the corner.
Studies show that the longer ‘‘L’’ shaped dispensed brack-
ets can significantly improve mechanical reliability (i.e.,
one study showed an improvement in shock performance
where the acceleration level caused the onset of mechani-
cal damage to occur, increasing from 180 G to 300 G.)
A good starting point for the amount of glue that should be
applied at each corner is that each leg of the ‘‘L’’ shaped
bracket should extend somewhere between 3 and 6 solder
balls deep. One pitfall of corner glue is using too little glue
in terms of the surface covered. Testing has shown that a
single dot of glue that covers no more than the width of
one solder ball down the side of the substrate does not sig-
nificantly increase the shock or bend performance of a
BGA. This is because typically the strength of the solder
mask to underlying FR-4 or the strength of the BGA sub-
strate is low and these constructions crack very easily if the
surface area of the corner glue is too low (see Figure 7-17).
Other guidelines are that the glue should wet on average at
least 50% up the vertical side of the substrate throughout
the entire dispense line and that the epoxy material should
be forced to flow to some degree underneath the BGA
package, even if the epoxy flows in deeply enough to con-
tact some of the solder balls.
Typical dispense equipment for post-reflow corner glue
includes a pneumatic source that supplies air to a syringe
and needle set up. This equipment is low cost and condu-
cive to being set up in manufacturing environments where
labor rates are fairly low compared to available capital.
Corner glues are epoxies similar to underfills. Typical cure
cycles include 5-60 minutes at 60-180°C. Some UV light
curable versions of these materials are also being intro-
duced.
7.2.3 Depaneling of Boards and Modules The method
for depanelization can be achieved using a number of
different techniques. These include simple scoring, a com-
bination of routing and scoring, and a combination of rout-
ing plus breakaway tabs (see IPC-2222).
Scoring is the machining of a shallow, precise V-groove
into the top and bottom surfaces of the laminate. As scor-
ing allows the removal of rails and individual parts from a
pallet, positional accuracy is critical. Routing defines the
final assembly periphery. The routing channels are pro-
duced using router bits of different diameters, leaving
breakaway tabs to hold the board in place during assembly.
Extreme care should be taken when breakaway tabs are
removed. Avoid bending the board, especially near BGA
components. Bending may cause BGA solder joints to
crack, typically starting with the corner balls. Custom tools
Figure 7-15 Corner Applied Adhesive
IPC-7095c-7-16
Figure 7-16 Critical Dimension for Application of Prere-
flow Corner Glue
Figure 7-17 Typical Corner Glue Failure Mode in Shock if
Glue Area is Too Low - Solder Mask Rips Off Board and
Does Not Protect the Solder Joints
IPC-7095C January 2013
90
Copyright IPC-Association Connecting Electronics Industries
Provided by IHS under license with IPC
Not for Resale
No reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---

should be fabricated, or machines designed for breakaway
tab removal should be purchased. These tools or machines
should reduce or eliminate stress near BGA components
during breakaway tab removal.
7.3 Inspection Techniques The following paragraphs
are inspection techniques that may be applied at different
times during the development of the BGA assembly pro-
cess or as an auditing mechanism during production. Table
7-4 provides some recommendations as to applicability of
the inspection method.
7.3.1 X-Ray Usage X-ray inspection is generally used
when there is a high proportion of hidden solder joints that
are not visually accessible, and when there are a significant
number of untestable solder joints. Examples of untestable
solder joints are redundant connections, and back-to-back
BGAs where the fanout vias are inaccessible and space
does not allow for additional test points. X-ray methods
can complement the test process chosen, and can provide
faster feedback to the manufacturing line. Depending on
the capability of the X-ray system being used, X-ray is
capable of detecting solder related defects such as bridging,
open solder joints, insufficient solder, and excessive solder
volume. Other defect types such as missing balls, misreg-
istration, and package popcorning can also be identified. In
addition to defect detection, X-ray can be used to provide
trend analysis for solder volume and solder joint shape.
X-ray is the only nondestructive method of finding voids in
BGA joints.
Figure 7-18 shows the principles of X-ray equipment being
used with the X-ray to be above the sample; some equip-
ments have the tube below or at an angle to the specimen.
The general characteristics provided in the figure apply to
most X-ray systems. X-ray inspection has become a gener-
ally accepted tool for solder joint evaluation and analysis,
and as a monitor for the reflow process. X-ray inspection
techniques can be employed most effectively through the
understanding of principles of X-ray image acquisition.
X-ray can be effective in confirming solder bond integrity
of BGAs and as a monitor for the reflow process. X-ray
inspection techniques can be employed most effectively
through the understanding of:
• Principles of X-ray image acquisition
• Analysis of the X-ray image (in the light of the reflow
process)
Use of X-ray requires some caution regarding overexpo-
sure on vulnerable materials or components. Figures 7-19
and 7-20 show the characteristics of X-ray images for both
voids at the interface, or missing solder balls in the BGA
attachment.
7.3.2 X-Ray Image Acquisition
7.3.2.1 Film Based X-Ray Inspection
Film based X-ray
inspection systems employ an industrial X-ray cabinet and
X-ray film packets to record the X-ray image on film. The
film can then be viewed on video film viewers for high
magnification examination of details. The process is slow
but can yield X-ray images of great detail and tonal accu-
racy.
7.3.2.2 Real Time X-Ray Systems Real Time X-ray
inspection systems utilize an X-ray source and a detector
system which converts the invisible X-ray image into a
video display signal. These systems provide immediate
imaging results of samples. The images produced from
these systems should not be distorted or include false arti-
facts induced by the X-ray system itself. Figure 7-21 illus-
trates a comparable level of image quality that should be
expected from a manual X-ray inspection system. Figure
7-22 illustrates examples of pin-cushion distortion and
voltage blooming. Real time systems are available in a
broad range of sizes from small desktop systems to large
Table 7-4 Inspection Usage Application Recommendations
Method
Process
Development
In-Line
Production
Failure
Analysis
Process
Auditing
NPI or Low
Volume
Production
Optical Inspection Excellent Good Excellent Good Good
Manual X-ray Excellent Good Excellent Good Excellent
Automated Transmission
X-Ray
Excellent Excellent Good Good Good
Automated Cross Section
X-Ray
Excellent Excellent Excellent Good Good
Scanning Acoustic Microscopy Excellent Fair Good Good Fair
Stand Off Measurement Fair Fair Good Good Fair
Automatic Optical Inspection
Solder paste
volume
Part
identification,
solder paste
volume
Not Applicable
Part
identification,
solder paste
volume
Part
identification,
solder paste
volume
Destructive Analysis Good Poor Excellent Fair Fair
January 2013 IPC-7095C
91
Copyright IPC-Association Connecting Electronics Industries
Provided by IHS under license with IPC
Not for Resale
No reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---