IPC-7095C-2013.pdf - 第88页

board thickness, etc. The test plots should be employed to verify that the data matches the requirements. Other documentation may include numerical control data for drilling, routing, libraries, tests, artwork, and speci…

100%1 / 176
previous case, the printed circuit board supports the weight
of the heat sink when the clips are actuated, but some stress
can still be transferred on to the BGA solder balls during
mechanical shock and vibration. In addition, the heat sink
may create a cantilevered load on the solder joint when the
assembly is in a vertical orientation. This load may lead to
premature solder joint failure.
Figure 6-36 shows the case of a heat sink attached to a
BGA package with clips that hook on stakes that are wave
soldered into holes in the printed circuit board. This
method of attachment transfers even less stress on the BGA
solder balls during mechanical shock and vibration than the
previous case. However, the solder joints of the stakes will
bear most of this stress.
Figure 6-37 illustrates the attachment of the heat sink to a
BGA by directly soldering the heat sink into the board dur-
ing the wave soldering process step. The heat sink design
has four or more pins that insert into holes in the board
prior to the wave solder process. As opposed to the previ-
ous cases above, this method does not need any post
assembly processing to attach the heat sink.
The three methods in Figures 6-30, 6-31 and 6-32 have one
drawback not present in the first two. These methods
require holes in the printed circuit to be designed in. These
holes may reduce the trace routing real estate on all the
board layers. For highly dense board designs, this could
impact the final layer count of the board.
6.8 Documentation and Electronic Data Transfer The
documentation package for describing BGA components
usually consists of a master drawing, master pattern draw-
ing, copies of artwork (film or paper), mounting structure
assembly drawing, parts list, and schematic/logic diagram.
The documentation package may be provided in either hard
copy or electronic data. All information about documenta-
tion is also appropriate for electronic data transmission.
Since many CAD systems have their own native database,
everyone is promoting some form of unique format that has
a neutral concept, thus avoiding sending the native data-
base to the suppliers.
The lowest common denominator for years has been a
machine language. This may eventually be replaced by
such formats as the IPC-D-356, or IPC-2581. Archiving
electronic data should be in accordance with these docu-
ments. Delivery of computer generated data as a part of the
documentation package should meet the requirements
stated in those packages. With automated techniques, the
database shall detail all information that will be needed to
produce the printed board or mounting structure for the
bare die. This includes all notes, plating requirements,
IPC-7095c-6-36
Figure 6-36 Heat Sink Attached to a BGA with a Clip that Hooks onto a Stake Soldered in the Printed Circuit Board
Grease/
Gel/PCM
Board
BGA
Heat Sink
Clip
IPC-7095c-6-37
Figure 6-37 Heat Sink Attached to a BGA by Wave Soldering Its Pins in a Through-Hole in the Printed Circuit Board
Grease/
Gel/PCM
BGA
Heat
Sink
Pin
Board
January 2013 IPC-7095C
73
Copyright IPC-Association Connecting Electronics Industries
Provided by IHS under license with IPC
Not for Resale
No reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---
board thickness, etc. The test plots should be employed to
verify that the data matches the requirements.
Other documentation may include numerical control data
for drilling, routing, libraries, tests, artwork, and special
tooling. There are design and documentation features/
requirements that apply to the basic layout, the production
master (artwork), the mounting structure itself, and the end
item component or printed board assembly. All must be
taken into consideration during the design of the mounting
structures for the bare die, or the mounting structure for the
BGA. Documentation shall meet the requirements of IPC-
2611. In order to provide the best documentation package
possible, it is important to review IPC-2611 and identify all
the criteria that are affected by the design process.
6.8.1 Drawing Requirements During the formal design
review prior to layout, special tools that can be generated
by the design area in the form of artwork or numerical
control data shall be considered. This tooling may be
needed by fabrication, assembly, or testing. Examples of
such tooling are drilling data files, solder paste stencils,
data for component placement, ICT fixture data, and art-
work in the form of layered graphics, silk screen and sol-
der mask.
When viewing the documentation, it is always viewed from
the primary side. All phototool generation is viewed from
that same direction. The definition of layers of the product
shall be viewed looking through the particular part from
the primary side.
Accuracy and skill must be sufficient to eliminate misinter-
pretation during the artwork generation process. This
requirement can be minimized by adhering to a grid or
pitch of the component terminations, which drive so many
features on the board or the bare die.
Layout notes should be as complete as possible with the
addition of appropriate notations. Marking requirements
and revision status level definition are key to maintaining
configuration management conditions. It is especially
important for the engineering review cycle, a quoting
effort, and when the document is used by someone other
than the originator.
6.8.2 Equipment Messaging Protocols Throughout the
electronics industry manufacturing consists of numerous
steps, each of which often centers around one suppliers
equipment. Although the steps are generally well-
automated within themselves, they are only peripherally
connected to one another. Proprietary data formats and
communications protocols prevent the islands of automa-
tion from talking to one another. This condition also pre-
vents factory managers from monitoring, understanding,
and possibly correcting the manufacturing process to
improve throughput and product quality.
In the last few years, building on an International Electron-
ics Manufacturing Initiative (iNEMI) funded project, the
IPC has standardized data syntax and semantics in elec-
tronics assembly, establishing rules for data exchange both
on a single factory floor and between that floor and the rest
of a manufacturing organization. The results have been
published as the IPC CAMX (computer-aided manufactur-
ing using the extensible markup language [XML]) stan-
dards: The standards are:
• IPC-2541, Generic Requirements for Electronics Manu-
facturing Shop-Floor Equipment Communication
• IPC-2546, Sectional Requirements for Shop-Floor Equip-
ment Communication Messages (CAMX) for Printed Cir-
cuit Board Assembly
• IPC-2547, Sectional Requirements for Shop Floor Equip-
ment Communication Messages (CAMX) for Printed Cir-
cuit Board Test, Inspection and Rework
At the heart of the standard is a framework with an inter-
mediary. This is the ‘message broker that handles infor-
mation exchange and complies with the IPC-2501 Standard
(‘‘Definition for Web-based Exchange of XML Data’’). The
message broker can be thought of as a post office or a mail
server. Messages are sent to the server and, when the infor-
mation is needed, it is asked for by the equipment or the
manager who wants the data.
In a factory, several lines of equipment and several appli-
cations may connect to the message broker at the same
time. Individual elements need not know any details about
the nature, configuration, or format of the others. They
communicate directly only with the broker. When people
and equipment need specific information, the broker pro-
vides it in the correct format.
6.8.2.1 Implementation It is relatively easy to set up the
infrastructure and web-based tools to monitor several sets
of manufacturing equipment, including in-circuit testers,
and several suppliers’ pick-and-place machines. The setup
can be used to gathered performance and functional feed-
back data on the message broker. The message broker can
usually be up and running in two days, being able to con-
nect reasonably easily with both legacy equipment and any
XML-ready equipment using an infrastructure that is in
place at the manufacturing site. In a careful installation, it
is also possible to avoid compromising network security
requirements.
Using internet standards like HTTP and XML ensures the
interoperability between different platforms. Although an
application has never been run against a running message
broker before, it can be adapted to the existing communi-
cation framework on site. One important goal of the IPC-
CAMX standards is to lower the technological barrier to
ease the integration of sophisticated equipment like pick-
and-place machines and test equipment, as well as simpler
equipment like printed board handlers. The CAMX stan-
dards provide data about the products under manufacture,
IPC-7095C January 2013
74
Copyright IPC-Association Connecting Electronics Industries
Provided by IHS under license with IPC
Not for Resale
No reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---
the processes, and the shop-floor equipment. Applications
receiving messages from the equipment include:
• Work-in-process (WIP)
• Tracking, capacity, and throughput monitors
• Equipment utilization and line-balancing monitors
• Product quality monitors that incorporated data from test
and inspection
Linking all parts of a manufacturing operation through a
single hub has been the goal for many years. The CAMX
message-broker approach provides an extraordinary array
of tools to accomplish that task. The message broker can
connect any number of clients together. Clients can be fac-
tory equipment, a host computer, or the data hub at the
engineering managers desk. The system provides visual
representation of whatever the manager wants to know. The
manager can communicate with someone in Singapore, and
check the status of their work-in-process using a snapshot
of the data in any of a number of preset formats. He can
pick the format and instruct the software as to how fre-
quently the updates are required, and the broker does the
rest.
6.8.2.2 Information Exchange Benefits Major equip-
ment manufacturers have involved themselves in this effort
from the beginning, thus they support the CAMX effort to
extract information from their machines in the standard
format. Critical to the success of this new tool is its ‘plug-
and-play’ construction. Any piece of equipment on the
floor can connect to the supporting architecture and data-
gathering software. Using XML as the standard ensures
that no one will misinterpret what the data means. Process
correction and product improvement require traceability of
faults, regardless of where a fault is identified. Knowing
where the fault came from and its root cause are critical.
In addition, increasing product quality and reducing costs
require understanding the actual fault spectrum. Histori-
cally, the same fault may be called by several names at dif-
ferent process points. Applying the CAMX standard, fault
names can be consistent from step to step within the manu-
facturing operation, thereby improving the overall level of
communication.
For electronics manufacturing service (EMS) providers, the
CAMX standards permit manufacturing flexibility without
sacrificing data coherence and comprehensive data analy-
sis, regardless of the process under evaluation. The soft-
ware is more streamlined and less complex than systems
that were developed for the semiconductor industry
because all of the equipment now conforms to the single
standard. The result is equipment that is both easier to use
and easier to support.
Standardization will open up opportunities to perform more
elaborate data analysis because the standards will reduce
the effort required to gather information. IPC-2501, as
implemented in the CAMX message broker, provides the
simplified web-based XML messaging activity for the other
IPC standard vocabularies. Equipment suppliers who need
a particular piece of information will merely ‘subscribe’
to an application or system using the existing Web-based
and universal XML messaging SOAP protocol, regardless
of the architecture of the other interfaces, and download
responses in real time. SOAP is an XML messaging stan-
dard supported by all major computing and software
vendors. It forms the foundation of their Web-services
infrastructures.
The XML message type of machine communication was
less necessary when OEMs did their own manufacturing.
However, with the amount of outsourcing that kind of ver-
tical integration has become more the exception than the
rule. The new standards will make it possible for the OEM
customer to regain a measure of the insight into manufac-
turing activity that was lost due to outsourcing the work.
The use of a universal data format will also provide the
ability of suppliers to monitor inventory of their products
to prevent disruptions of the manufacturing line. Compo-
nent suppliers can monitor usage of their components on
the factory floor, scheduling purchases and taking over
similar functions that otherwise fall to the EMS company
or to the OEM.
6.8.3 Specifications In many instances, documentation
references other specifications. These should be clear and
should be provided in this same manner in which the origi-
nal package is provided (hard copy or electronic). Confor-
mance test circuitry shall be provided, thus the part can be
tested through destructive techniques. As a minimum, con-
formance test circuitry shall include:
• Board part number/revision letter
• Assembly part number and reference to Bill of Material
• Traceability identification
• Date code
• Manufacturers identification, e.g., commercial and gov-
ernment entity (CAGE), logo, etc.
• Special coding systems may be used provided they are
identified on the master drawing
January 2013 IPC-7095C
75
Copyright IPC-Association Connecting Electronics Industries
Provided by IHS under license with IPC
Not for Resale
No reproduction or networking permitted without license from IHS
--`,,```,,,,````-`-`,,`,,`,`,,`---