TR7500E_Manual_en_v28.pdf - 第107页

C h a p t e r 2 M a nu a l B a r i n t r o d u ce T R 7500 U S E R M A N U AL 1 00 6 . O p e r a ti on 6 . 1 . A u t o M od e l A f t e r i n s p e c t i ng s y s t e m o u t pu t t h e r e s u l t a n d s t a r t t o i …

100%1 / 292
Chapter 2 Manual Bar introduce
TR7500 USER MANUAL
99
l Using the function to import a BOM file for a completing project is to set the
component that is not listed on BOM file as Untest. The format of BOM file is
in Chapter 3 1.1. (3).
5. Inspection
Start to inspect
Only show single board result
Inspect saved FOV images
Specify single to test or not
5.1. Inspect Panel
l Start to inspect the PCB with standard procedure.
5.2. Debug for Single Board Set
l Start to inspect, but it shows only the result of one set.
5.3. Inspect FOV Images
l Inspect the FOV images that are saved in hard disk.
5.4. Manual Skip Board Setting
l You can use this function to specify every single board to be tested or not.
l As the image below, click on the board directly; the green [O] means that the
single have to be inspected and the red [X] means that the single board doesnt
have to be inspected. Then press [OK] to finish sitting.
Chapter 2 Manual Bar introduce
TR7500 USER MANUAL
100
6. Operation
6.1. Auto Mode
l After inspecting system output the result and start to inspect the next PCB
directly.
6.2. Confirm-Pass Mode
l After inspecting system output the result. The next PCB will be inspected until
operator confirm.
6.3. ByPass Mode
l The output is always Pass
Chapter 2 Manual Bar introduce
TR7500 USER MANUAL
101
6.4. Auto-Confirm Mode
l After inspecting system output the result and start to inspect the next PCB
directly. And the defect map will be shown as double size its easy for operator to
confirm the defects on AOI machine.
6.5. On Machine Confirm
l The function is only for [Confirm Pass Mode]. When you select the function
there must be an operator to confirm the PCB on AOI Machine. The data transfer
to repair station are confirmed and dont have to confirm again.
l Right click on defect tree and confirm the defect is pass, fail or no firm. You also
can use keyboard to select, [F8] means [Confirm Pass], [F7] means [Confirm
Fail] and [F6] means [No Confirm]. [No Confirm] means the result is the same
as the result of whole board. If you select [Pass] for whole board the result for
every defects will be set as [pass] automatically no matter what you confirmed
respectively.