TR7500E_Manual_en_v28.pdf - 第288页

C h a p t e r 8 O ff l i n e E d i t or T R 7500 U S E R M A N U AL 2 81 l S e l e c t [ P a r a m e t e r \ P a n e l \ O f f li n e S t a t i on ] a n d s e t t h e p a t h l i n k t o t h e s p e c i f i e d f o l d e…

100%1 / 292
Chapter 8 Offline Editor
TR7500 USER MANUAL
280
(8) When the size of the component goes beyond the range of one FOV, you still
have to edit this type on TR7500E.
(9) Save the all component library (*.pgl).
(10) Copy the [PackageLibrary] and [ImageLibrary] folder to TR7500E. The default
path is [C:\AOI\packagelibrary] and [C:\AOI\imagelibrary].
(11) Continue the ATPG process to finish: [Merge]à[FOV Generate]à[FOV Verify].
(12) Save the *.pre file.
3.2. Train Dialog
(1) Copy the whole folder where the project saved in to offline editor. PRE.
(2) Execute the main program on offline editor and open the *.pre file.
(3) You can train inspection boxes according to Chapter 1 10. Because you cant
grab image on offline editor, you only can edit on existing image and you cant
change the lighting.
(4) If you ever do [Merge] when editing, system shows a dialog that remind you that
the system cant get image. So you have to get FOV images again while getting
back to TR7500E.
(5) Save the project and copy the project to TR7500E. And you can do inspection or
fine tuning.
4. Auto Feedback Function
4.1. Objective
l Transferring the inspecting result to Offline Editor and getting the feedback from
Offline Editor.
4.2. Setting
4.2.1. Diagram
4.2.2. Hardware
l Connect AOI machine and Offline Editor with cross over cable.
4.2.3. About Offline Editor
l Create a [AOI_Offline_Data] in C Disc.
l Select [Parameter\User Mode\Link To Machine].
Offline
Editor
TR7500E
(*.pnl)
(*.fbk)
[//OfflinePC/C/
AOI_Offline_Data]
Chapter 8 Offline Editor
TR7500 USER MANUAL
281
l Select [Parameter\Panel\Offline Station] and set the path link to the specified
folder. For example, if you want to save the offline data in repair station, the path
has to be appointed to a folder in repair station pc.
4.2.4. About TR7500E Machine
l Select [Parameter\User Mode\Link To Offline Station]
l Select [Parameter\Panel\Offline Station] and set the path link to the specified
folder. This path must link to the folder that is the same with what offline editor
appoints to.
4.3. Operation Instruction
l Result Dialog
(1) Copy the testing project and the [FOV Image] folder to Offline Editor.
(2) When TR7500E has tested one time, the failed image and [*.pnl] file are
transferred to the [AOI_Offline_Data] folder of Offline Editor.
(3) Open the main program and load the [*.pre] file that is the same with the
inspecting project at TR7500E main machine.
(4) Press [Inspection\Inspect FOV Images] then the system start to inspect the saved
FOV images. If the TR7500E have sent the failed image, the system uses these
failed images in place of the saved images and inspects them. You can set search
range, pass level or add alternative images according to the inspection result.
(5) Press [Confirm PASS] or [Confirm FAIL] then this data is canceled and the next
result is appeared.
(6) When you change the setting at Offline Editor, the system saves a [*.fbk] file in
[AOI_Offline_Data] folder. When AOI is transferring a data to Offline Editor, it
reviews the [*.fbk] file at the same time and the inspection parameters are
modified at the next inspection.
l Train Dialog
(1) Press [Train] to enter train dialog.
(2) Click on an inspection box that you want to review the result.
(3) Right click on the inspection box and select [View\ Show Data Collection Chart
of this Box]. The system shows the latest 1000 data of this box.
(4) You can change the search range, pass level or add an alternative image in this
window.
Appendix 1 Lighting Compensation
TR7500 USER MANUAL
282
Appendix 1 Lighting Compensation
1. Lighting Compensation
Ø This function can carry on the lighting compensation to camera with the
software. The standard is that when lighting range is established as 60mA and
intensity is 128 at all adjusted zones the gray level of the gray card image is
compensated to 100.
Step1. Press [Start/Run/ Key in regedit] to open the registry. Enter
HKEY_LOCAL_MACHINE\HKEY_LOCAL_MACHINE\SOFTWARE\TR
I\ and check if there is a DWORD variable named LightingCompensation.
If there is not the variable, you can open the main program of TR7500E and
the variable is created automatically.
Step2. If you want to execute lighting compensation, you can change the value of the
variable to 1.
Step3. When you execute the lighting at the first time, the system creates the
following 3 parameters. [CenteralGrayRGB0], [CenteralGrayRGB1],
[CenteralGrayRGB2] are represented the objective gray level for R, G, B
sensors.
Step4. Open the mail program of TR7500E and enter [Utilities/Camera Alignment].