TR7500E_Manual_en_v28.pdf - 第196页

C h a p t e r 3 A O I A T P G F u n c t i o n i n s t r u c t i on T R 7500 U S E R M A N U AL 1 89 10.7.2. Pr o p e r t y l S e t p r op e r t y o f i n s p ec t i o n bo x . l ( p i n - 1 ) – D i s p l a y s t h e s e …

100%1 / 292
Chapter 3 AOI ATPG Function instruction
TR7500 USER MANUAL
188
Step4. Give the new logic setting a name, and input it in [Defect] field.
Then press [New Defect] to create the new logic.
Step5. When the logic contains an inspection box that is belonging to an
IC lead, the system will ask you if you want to copy the same
logic to the other leads. You can select Yes or No according to the
situation.
Chapter 3 AOI ATPG Function instruction
TR7500 USER MANUAL
189
10.7.2. Property
l Set property of inspection box.
l (pin-1) Displays the serial number of the IC pin that the selected
inspection box inspects. When showing (pin-1), it means that the selected
box doesnt inspect any IC pin.
l Component Type Displays the component type
l Name Displays the inspection box name
l Angle Displays the rotation angle of the component. When the angle
defined in CAD file, you can modify it here.
l X Component on the X coordinate position.
l Y Component on the Y coordinate position.
l DX The component X coordinate on the center.
Chapter 3 AOI ATPG Function instruction
TR7500 USER MANUAL
190
l DY The component Y coordinate on the center.
l Test Select TRUE is enable inspection, FALSE is disable inspection.
l Camera Select Top Camera view.
l Lighting Select Light type.
l Method Select the inspection windows for property change.
l Search Range Select this item to set the search range for [Missing] or
[Lead] box manually. After you set, the later X and Y field display the range
(unit: um). The X and Y field are just for review and cant be filled. If the
range is not set, the X and Y field display 0 and the system sets the range
automatically.
Step1. Open [Property] dialog and check [Search Range] then you can see a
thick line and purple frame on the painting area.
Step2. Click on the box that you want to set and then adjust the purple
frame to suit the search range. The search range cant be smaller
than the inspection box.
Step3. Press [Set] then the setting is finished. The X and Y field display the
length and width of search range.
Step4. The search range displays by thin line and purple frame.
l Image Group When the components with the same type but in different
groups, you have to set the image for different group. You can see more
about group in Chapter 3 2.
l ADD Add image to component image library from missing or lead
inspection windows.
l Remove Remove the select image to component image library.
l Mask Masking the component image with the non-inspection area or