C h a p t e r 7 S t a r t t o I n s p e c t i on T R 7500 U S E R M A N U AL 2 78 ( 2) P r e ss b u t t o n t o c l o s e t h e T R 7 5 0 0 E m a i n p r o g r a m . At t h e s a m e ti m e t h e s y s t e m a s k s i f …

Chapter 7 Start to Inspection
TR7500 USER MANUAL
277
(2) Check [Parameter/Panel/Barcode/Check Bar Code]
4. Link to Repair Station
(1) Select [Parameter/User Mode/Link to Repair Station]
(2) Set the path in [Parameter/Panel/Repair Station] directing to
[//RepairPC/C/AOI_Repair_Data]
(3) Select [Utilities/Resend Image Data to Repair]
(4) Save the project and start to inspect.
5. Inspect on Another Machine
(1) Copy the project (*.pre ) and panel map to another AOI machine.
(2) Select[Utilities/Fiducial Mark Alignment]
(3) If the system can’t find the fiducial mark you should change the fiducial 0
position. Select [Utility/Fiducial Mark Setting] to set the position of fiducial 0.
(See Chapter 2 7.5. )
(4) Start to inspect.
6. Stop testing and shut down
(1) Press the Esc key on keyboard to stop the project that is testing.

Chapter 7 Start to Inspection
TR7500 USER MANUAL
278
(2) Press button to close the TR7500E main program. At the same time the
system asks if you want to save the project and you can choose to save according
to your own demand.
(3) Select [Start/Shut down] to close down the TR7500E main pc.
(4) Turn the power switch counterclockwise to shut down the machine.
(5) Close the breaker.

Chapter 8 Offline Editor
TR7500 USER MANUAL
279
Chapter 8 Offline Editor
1. Software
(1) Sapera LT
(2) Cognex Driver
(3) TR7500E main program. Must the same with the TR7500E what you
2. Setting
l Select [Start\Run] and key in [regedit]. Under the path
[\\HKEY_LOCAL_MACHINE\SOFTWARE\TRI] you should add a DWORD
parameter named [offline] and change the value to 1.
3. Procedure
l There two parts you can use on offline editor. One is editing component library
and the other is training in main program.
3.1. Editing component library
(1) Start to create a project according to Chapter 1 . After finishing step 5, setting
fiducial mark, you enter the editing component library window. (Click on [Tune]
page below the ATPG flow chart then selects [Library]. And double click on
[Component Type] item.)
(2) Select [
Tool/Capture Image/ All Type] button then the system captures the
first component (ranked by name) images for all type. There are total 2 images
will be captured for every first component, captured by top camera with
[ToplightA] and [ToplightB].
(3) System will create a new folder named as [OfflineImage] in the folder that
project file is in. The images are named by its type and component name.
(4) Save the project (*.pre).
(5) Copy the whole folder where the project saved in to offline editor. If you want to
continue editing the existing component library you have to copy the
[PackageLibrary] and [ImageLibrary] folder to offline editor.
(6) Execute the main program on offline editor and open the *.pre file.
(7) Select [Program\ ATPG] to enter the ATPG editing window. Click on [Tune]
page below the ATPG flow chart then select [Library]. And double click on
[Component Type] item. Then you can start to edit the component library
according to Chapter 3 10.9.