TR7500E_Manual_en_v28.pdf - 第185页
C h a p t e r 3 A O I A T P G F u n c t i o n i n s t r u c t i on T R 7500 U S E R M A N U AL 1 78 10.6.5. C a p t u r e I m a g e l C a p t u r e i m a g e s f o r o f f li n e e d i t o r t o e d i t p r o j e c t . S…

Chapter 3 AOI ATPG Function instruction
TR7500 USER MANUAL
177
10.6.4. Move Center
l In image frame you can press [Move Center] to move the camera to component
center.

Chapter 3 AOI ATPG Function instruction
TR7500 USER MANUAL
178
10.6.5. Capture Image
l Capture images for offline editor to edit project. System will create a new folder
named as [OfflineImage] in the folder that project file is in. The images are
named by its type and component name.
l Current Component – Just capture the component that you edit now. There are
total 2 images will be captured, captured by top camera with [ToplightA] and
[ToplightB].
l All Type – For all types capture the first component (ranked by name) the 2
images explained before.
10.7. Setting
Set Algorithm
Set Property
Set Pass level
Set the director of library
Set the rule of directivity for IC pins
10.7.1. Algorithm
l Set algorithm for different inspection boxes in the component.
10.7.1.1 All functions

Chapter 3 AOI ATPG Function instruction
TR7500 USER MANUAL
179
l Defect – The output inspection defect name.
l Operator – The defect logic operation operator. There are three options in
this field, [&(AND)], [|(OR)] and [^(XOR)].
n &(AND)– Show pass if all of the selected windows are passed.
n |(OR)– Show pass if one of the selected window is passed.
n ^(XOR)– Show pass if the pair of selected windows are not with the
same result.
l Logic – Setting the logic operation formula. Double click on the list window
and the formula will be moved to [Logic] field.