TR7500E_Manual_en_v28.pdf - 第240页

C h a p t e r 4 T r a i n d i a l og f u n c t i on T R 7500 U S E R M A N U AL 2 33 l Y e s – C o p y t h e s i z e a n d po s it i o n t o t h e r e l a ti v e c om p o n e n t o n t h e o t h e r mu l t i - b o a r d …

100%1 / 292
Chapter 4 Train dialog function
TR7500 USER MANUAL
232
(2) Copy You can copy the size or position to the other components with
same type.
Chapter 4 Train dialog function
TR7500 USER MANUAL
233
l Yes Copy the size and position to the relative component on the other
multi-board. If the inspection box is trained the setting cant be
changed.
l No Just copy the size to the other components.
(3) Save Image Save the FOV to the folder that the SOL file saves in. The file
name is composed by date and time.
(4) Set Weighting The View Model widow shows after pressing the button.
Then you can set the weighting for specified image. See Chapter 4 6.2.6. for
more information about set weighting.
(5) Link Box You can assign windows that are parents and children to link.
See more about link in Chapter 3 10.2.2.
(6) Unlink Box You can press [Unlink] to break the link between windows.
See more about unlink in Chapter 3 10.2.3.
(7) Copy Box Copy the selected inspection box in the system.
(8) Cut Box Cut the selected inspection box in the system.
(9) Paste Box Paste the box that copy or cut before. Select a box and press
[Cut Box] or [Copy Box] first then press [Paste Box] at the objective FOV.
The inspection box does not appear now, and you have to move the mouse
to the correct position and left click on the image; then the dialog below
appeared. After you input the information of the component and press [OK],
the inspection box is visible. If there are other components in the range of
2mm near newly-increased component, it is unable to stick the inspection
box.
Chapter 4 Train dialog function
TR7500 USER MANUAL
234
(10) Move to Left FOV Move the selected box to the left FOV.
(11) Move to Right FOV Move the selected box to the right FOV..
(12) Rotate Box Side Rotate the pin direction with 90 degrees of
counterclockwise for clicking once.
(13) Set Logic Set the Logic between windows. See more about logic in
Chapter 3 10.7.1. .
(14) Inverse Logic Checks this item to start the [Inverse Logic] function. After
you select this function, the system regards a box that is passing the pass
level as failed and a box that is not passing the pass level as passed.
(15) Test Set the selected inspection box as [Test Box] or [Test component].
It establishes it with [untest] correspond to
(16) Untest Set the selected inspection box as [UnTest Box] or [UnTest
component]. [UnTest Box] means only set the selected box as untested and
the box become blue; [UnTest Component] means set the all boxes in
selected component as untested and the boxes become gray.
(17) Set to Library Sent the information of [Pass Level] or [Search Range] of
the selected box to Library. You can only select the inspection boxes that is
belonging to a component. And [Weighting] is only for TR7500E series.