FLEXLINE-CAD_INM.pdf - 第103页
A-6 5.2 Field definition scre en The PW B data of T utorial.txt cont ains "PW B ID", "PW B outer dimensions", "PW B layout of fset", and "BOC mark coordinates." Try to defi ne them…

A-5
5. PWB Section
Next, the screen to define PWB data (first, "Section definition screen") is displayed. Click the
"Refer" button to display the "Open" dialog box. Select Tutorial.txt provided in the {Flexline CAD
install folder}\SampleData\" folder.
5.1 PWB Section
● Section layout
In this example, PWB data is provided on line 1 to line 6 (actually line 2 to line 5.
Accordingly, select the "Line range" in the "Section layout" list and enter 1 in the "Start line"
and 6 in the "End line."
● Field layout
From the "Field layout list", select "Field."
Figure A-8 Section definition screen (PWB)
After completing the setting, click the "Next" button.

A-6
5.2 Field definition screen
The PWB data of Tutorial.txt contains "PWB ID", "PWB outer dimensions", "PWB layout offset",
and "BOC mark coordinates." Try to define them in "Field."
5.2.1 Specifying the field position
Click and drag the mouse and define the field. In this example, there are nine fields.
Data
Section start line
Start column
End column
Flexline CAD Tutorial PCB
2
1
24
150000
3
5
10
100000
3
15
20
150000
4
5
10
000000
4
15
20
10000
5
6
10
10000
5
16
20
145000
5
25
30
95000
5
36
40
* "Line" and "Column" are data position information and values are entered automatically.
Try to define the first field. (Specify the position and define the contents on the next screen.)
Figure A-9 Field definition screen
Define the above nine fields according to the same procedure.
①
Click on the first character "F."
②
Drag it to "B" by clicking to select this line.
③
Click on "Add field."

A-7
5.2.2 Defining the field
Check whether the field position is correctly set. If it is wrong, select the line of the wrong field
and click the "Delete Field" button to delete the field. After deletion, set the correct field position
again.
◊ Define the PWB ID field.
Figure A-10 PWB data field
Likewise, set each field as shown below:
Field name
Section start line
Start column
End column
PWB ID
2
1
24
PWB outer dimensions C
3
5
10
PWB outer dimensions Y
3
15
20
PWB layout offset X
4
5
10
PWB layout offset Y
4
15
20
BOC mark position No.1 X
5
6
10
BOC mark position No.1 Y
5
16
20
BOC mark position No.2 X
5
25
30
BOC mark position No.2 Y
5
36
40
After completing the definition, click the "Next" button.
① Click here to display the list.
② Select the PWB ID from the list.