FLEXLINE-CAD_INM.pdf - 第125页

C-5 ♦ "Panas onic" There are two t ypes of Placement data files as follows :  .NCD dat a file  .POS dat a file The following table describes the relationship among the Panasonic machine name, machine number ,…

100%1 / 145
C-4
"MK1C" and "MV1"
Now, there is no difference in contents between MK1 and MV1.
Data filed names that can be translated
PCB data
Placement data
Component data
Not translated
Placement ID
Not translated
Placement position X
Placement position Y
Placement angle
Component name
Format definition
Data section
Section layout
Tag name
PCB data
Placement data Tag format
GOMO
A sample
N0001/0G0M901T000X+002598Y+000500Z+00000V+00000W+00000 +00000D
N0002/0G0M901T000X-002180Y+000000Z+00000V+00000W+00000 +00000D
N0003/0G0M901T000X-004360Y+000000Z+00000V+00000W+00000 +00000D
N0004/0G0M901T000X-006540Y+000000Z+00000V+00000W+00000 +00000D
N0005/0G0M901T000X-006540Y-002850Z+00000V+00000W+00000 +00000D
N0006/0G0M901T000X-004360Y-002850Z+00000V+00000W+00000 +00000D
N0007/0G0M901T000X-002180Y-002850Z+00000V+00000W+00000 +00000D
N0008/0G0M901T000X+000000Y-002850Z+00000V+00000W+00000 +00000D
N0009/0G1M000T004X+000000Y+000000Z+00000V+00000W+00000 +00000D
N0010/0G0M004T000X+012034Y-021796Z+00001V+00090W+00090 +00000D
N0011/0G0M004T000X+012499Y-022541Z+00002V+00000W+00000 +00000D
N0012/0G0M004T000X+012214Y-021791Z+00002V+00090W+00090 +00000D
N0013/0G0M004T000X+012058Y-022155Z+00004V+00090W+00090 +00000D
N0014/0G0M004T000X+012814Y-022201Z+00005V+00090W+00090 +00000D
N0015/0G0M004T000X+012234Y-022151Z+00006V+00090W+00090 +00000D
N0016/0G0M004T000X+012234Y-022541Z+00007V+00090W+00090 +00000D
C-5
"Panasonic"
There are two types of Placement data files as follows:
.NCD data file
.POS data file
The following table describes the relationship among the Panasonic machine name, machine
number, file type and the input format names supported by Flexline CAD.
Table Pana-1 Panasonic Machines and Flexline CAD Input Formats
Machine
Name
Machine Number File Type
Input Format in Flexline
CAD
MPA 40 / 80 NM-2528
NM-2529
NCD MPA4080
MPA NM-2523
NM-2524
NCD
MPA
MK1C NM-2562C
NM-2565C
NCD
MK1C
MK2C
NM-2563C
NCD
MK2C
MK1 NM-2562
NM-2662B
NCD
MK1
MK2
NM-2563
NCD
MK2
MKH NM-2564 NCD MKH
MR NM-2560 NCD MR
MR 20 / 3
NM-2560
NCD
MR20
MQ1 NM-8256C
NM-8257C
NCD MQ1
MQ2
NM-8251C
NCD
MQ2
HD
NM-2621
NCD
HD
HD3
NM-2626C
NCD
HD3
MVI NCD MV1
MVIIA-B
NCD
MV2AB
MVII-C,F NM-2558
NM-2559
POS MV2C
MV2F
MPAIII
POS
MPA3
MSH1
POS
MSH1
MPA-V
POS
MPAV
The Panasonic data type uses two methods. XY coordinates can be entered with the absolute
method or the incremental method. Flexline CAD only supports ABS method.
Absolute method (ABS): Coordinate origin is always the basis for the placement position of
each component.
Incremental (INC): Placement position of each component is not determined from the
coordinates’ origin. Instead, it is determined to be the travel distance from the placement
position of the previous component. Therefore, X and Y coordinates represent the distance
from the center of one component’s placement position to the center of the next
component’s placement position.
C-6
.NCD Data File
.NCD Data Sample
Example 1 (MK2 data file):
N001/0G0M902T0X-18175Y-515Z1V1W1
N002/0G0M902T0X10750Y0Z1V1W1
N003/0G1M0T4X+Y+Z+V+W+
N004/0G0M4T0X6990Y6645Z20V1W1
N005/0G0M4T0X6990Y6420Z20V1W1
N006/0G0M4T0X6990Y6185Z20V1W1
N007/0G0M4T0X6990Y5505Z20V1W1
……
N051*
Example 2 (MV data file):
N0001/0G0M902T000X+000000Y+000000Z+00000V+00000W+00000+00000D
N0002/1G1M000T004X0000000Y0000000Z000000V000000W000000+00000D
N0003/0G0M001T000X+003001Y-008374Z+00001V+00090W+00090+00000D
N0004/0G0M001T000X+009876Y-008124Z+00001V+00000W+00000+00000D
N0005/0G0M001T000X-001549Y-018449Z+00001V+00090W+00090+00000D
N0006/0G0M001T000X-004374Y-024624Z+00002V+00090W+00090+00000D
N0007/0G0M001T000X-004399Y-025824Z+00003V+00090W+00090+00000D
………..
N0489/0G0M001T000X+012951Y-011099Z+00111V+00000W+00000+00000D
*
PCB Data
According to the placement data file, the field “PCB Board Typeis identified as shown in Table Pana-2
below:
Table Pana-2: Panasonic Data Format PCB Board Type
Data Item
Lines
Sections
Fields
Translation
PCB Board
Type
The first line
of the .NCD
data file
“SECTION_0” The field that is
tagged by the
keyword “M” in
the data line.
The string “901,” “902,” “911,” “912,”
“921,” “922,” “931,”or “932,” indicates
that the board is a “Non-Matrix Board."
Any other strings indicate that the
board is a “Single Board.”
If the result of the PCB Board Type is “Non-Matrix," the software will search the whole .NCD file and
pick up all the data lines with the M command tagged with string “901,” “902,” “911,” “912,” “921,” “922,”
“931,”or “932.” These lines will be regarded as the Non-Matrix data lines and the software will extract
the circuit position X and Y and Angle in the way described in Table Pana-3 as shown below: