Chapter 2 Daily maintenance items
Contents
1. Main unit 2-1
1.1 Checking tower signal & operator area indicator 2-1
1.2 Dehumidifier operation 2-2
2-1
2
Daily maintenance items
1. Main unit
1.1 Checking tower signal & operator area indicator
Check if the tower signals and operator area indicators work properly everyday.
If there is difference between the machine operation and these lighting, there might be something wrong with
the machine.
Tower signal & operator area indicator
Tower signal Operator area indicator
Operation
indicator
Power
indicator
Red
White
Green
Yellow
53201-KMS-00
Color Status
Signal tower lighting Red Emergency stop, Error occurs
Green In automatic operation
Yellow & Green In unloading components
White and Green In loading components
Yellow Components exist in loading/unloading area
Operator area indicator Operation indicator (green) All control boards are able to operate
Power indicator (white) Operation switch of the machine is on