8 Head exchange 8.7 Replacing the SIPLACE CPP/M Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 271 Removal NOTICE Vacuum test ► If required, perform a vacuum test before removing the placement head. Read the &quo…

8 Head exchange
8.7 Replacing the SIPLACE CPP/M
270 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
8.7 Replacing the SIPLACE CPP/M
Parts, equipment and tools
Fig.360: SIPLACE CPP with camera
●
SIPLACE CPP with camera SST29 [03070108-xx] or
SIPLACE CPP without camera [03053528Sxx]
●
SIPLACE CPP [03053528Sxx] (without camera)
●
SIPLACE CPP M [03153719Sxx] (without camera)
●
Torx screwdriver ESD 1.0-5.0 Nm [03078400-xx]
●
Extension/straight TX20 [03073256-xx]
●
Bit holder for TorqueVario screwdriver [03078706-xx]
●
Component sensor protective cap [03080984-xx]
●
Torx offset screwdriver TX8 [03080081-xx]
●
Calibration tool version 3 [03010565-xx]
●
Calibration tool version SST23 [03034148-xx]
●
Optional: upgrade kit for a cover over the intermediate distributor 2
Read also the technical information "Retrofit kit usability cover CPP" [DE:TI2018‑06D05]
[EN:TI2018‑06E05].
For additional work to the placement head:
●
Head mount [03056231‑xx]
●
Service manual "SIPLACE CPP" [DE:00197462‑xx] [EN:00197463‑xx]
●
Job Card "Preventive Maintenance CPP" [DE:00197505‑xx] [EN:00197503‑xx] (other lan-
guages available)
Overview
Fig.361: Overview (example of SIPLACE CPP head shown)
1. Fixture holes (two each, depends on in-
stallation height)
NOTICE!
The length of the exhaust air hose "Sil-
icon hose Di8 Da12 electrically con-
ductive 1m" [03006727Sxx] on the
SIPLACE CPP/CPP M is 316mm.
.

8 Head exchange
8.7 Replacing the SIPLACE CPP/M
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 271
Removal
NOTICE
Vacuum test
► If required, perform a vacuum test before removing the placement head.
Read the "Service manual Vacuum test at C&P placement head" [DE+EN:
00196101‑xx] for this.
NOTICE
Fast Hardware Exchange (FHE)
► Observe the instructions in section 8.1 "Fast Hardware Exchange" [}253] when ex-
changing a head.
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}86]
CAUTION
Take great care when dismantling the placement head!
The component sensor prisms, underneath the placement head, could be damaged.
► Never place the placement head down on the component sensor.
Fig.362: Component sensor protective cap
► Fit the protective cap onto the compo-
nent sensor for the placement head.
Fig.363: Connections
► Unplug the pneumatic connections(1)
from the placement head. You may like
to mark their positions, to make clear
assignment easier later on.
► Disconnect the flat ribbon cables(3)
from the intermediate distributor(2).

8 Head exchange
8.7 Replacing the SIPLACE CPP/M
272 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Fig.364: Cables (with GigE)
► Open the cable holder(1) and unplug
the component camera cable(2)
.
► Remove all four screws fastening the head with a long Torx screwdriver.
► Carefully lift the head out of the locating pins on the head plate and off the hook.
► Placing the head into the head transport box
► If you need to perform further work on this placement head (e.g. replacing spare parts), fit the
placement head to the head mount [03056231-xx].
Installation
► If you replace the head without the component camera, you will need to fit the old camera
onto the new head. Read the service manual for your placement head for more information.
► Observe the correct installation height of the head!
(for top and bottom installation position, see 8.7.1
"Preparing the SIPLACE CPP for the install-
ation height" [}273])
► Make sure that the assembly position on the head plate is correct.
► Tighten the four fastening screws with a torque of 2.7Nm.
► Make sure that the flat ribbon cable is run correctly to the head adaptor (see below).
Fig.365: Flat ribbon cable
Correct running of flat ribbon cable to
head adaptor
► Make sure that the flat ribbon cable is
run correctly to the head adapter. In
particular, the cables must lie inside
one another at the 90 degrees turn(1)
and not on top of one another, other-
wise the connections on the head
adapter could be easily confused.
Follow the removal instructions in reverse order for further installation.
See also
2 8.9 "Installation Positions on the Head Plate" [}278]