00198829-01_SM_X-Series-S_Hxxxx_EN.pdf - 第284页
9 Component feeding 9.1 Cutter 284 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 9.1.2 Venting compressed air at the cutter ► Switch off the compressed air supply 5.2 "Disabling the compressed air supply&qu…

9 Component feeding
9.1 Cutter
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 283
9 Component feeding
DANGER
Observe User Manual
► Please observe the safety instructions in the user manual for all work!
9.1 Cutter
DANGER
Observe User Manual
► Please observe the safety instructions in the user manual for all work!
WARNING
Risk of injury when working near the cutter.
When working in the area of the tape cutter, move the component trolley out of the machine
and disconnect the machine from the mains supply and the compressed air supply.
► Wait until the operating pressure has dropped to 0 MPa.
► Pull one of the thinner hoses off the Y distributor on the cutter, to vent the pneumatic
lines and the cutter (see 9.1.2
"Venting compressed air at the cutter" [}284]).
► After completing work to the cutter, you will need to connect the hose again.
► Always secure the machine against unauthorized reactivation.
► Do not reach into the tape cutter.
CAUTION
Risk of injury when performing service work on the tape cutter.
Never support the tape cutter on your body, e.g. on your knees or thighs. Do not place your
feet under the tape cutter.
► Wear appropriately thick protective gloves.
► Only hold and carry the cutter on the outer left and righthand parts.
9.1.1 Cutter
Fig.379: Overview of cutter [03066690‑xx]
1. Short stroke cylinder
2. Electrical connection
3. Solenoid valves

9 Component feeding
9.1 Cutter
284 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
9.1.2 Venting compressed air at the cutter
► Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}86]
Fig.380: Disconnecting the hose
► Carefully pull one of the two small
hoses(2)
of the Y-piece(1).
This enables any compressed air still
present in the system to be released.
CAUTION!
Risk of injury
The hoses could still be pressurized.
.
9.1.3 Replacing the waste tape slide
Parts, equipment and tools
●
Used tape chute complete [03067460-xx]
●
Allen key set
Overview
Fig.381: Waste tape slide
1 Waste tape slide 2 COT insert
3 Fastening screw for used tape chute, left 4 Fastening screw for used tape chute,
right

9 Component feeding
9.1 Cutter
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 285
Removal
► Remove the screws fastening the used tape chute.
► Take the used tape chute down and out of the machine.
CAUTION
Risk of cutting
The cutter is located under the tape channel. The blades there have very sharp edges.
► Do not reach into the cutter and make sure that it is never freely accessible.
Installation
► Follow the removal instructions in reverse order for installation.
9.1.4 Replacing the Cutter on the COT Insert [03066690-xx]
Parts, equipment and tools
●
Cutter, pneumatic SIPLACE HF/X-Series [03066690-xx]
●
Screw clamp
●
For additional work to the cutter:
Two large parallel clamps and a sturdy table with even surface, to clamp down the dismantled
cutter
Removal
NOTICE
COT insert
The cutter can be removed without dismantling the COT insert.
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}86]
► Vent the cutter. It must be totally depressurized.
9.1.2 "Venting compressed air at the cutter" [}284]
Fig.382: Connections
► Remove the four screws fastening the
waste tape slide(3)
and then remove
the waste tape slide.
► Unplug the compressed air connections
for the short-stroke cylinder (2)
at the
coupling.
► Unplug the electrical connections (4)
from the cutter(1). To do this, press the
sides of the connector.