00198829-01_SM_X-Series-S_Hxxxx_EN.pdf - 第325页

9 Component feeding 9.2 COT insert Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 325 Installation ► Installation is performed by following the above instructions in the reverse order. Also observe the following …

100%1 / 382
9 Component feeding
9.2 COT insert
324 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
9.2.10 Replacing the empty tape duct Einsatz
Read the relevant section of the user manual for your machine.
Parts, equipment and tools
Empty tape duct insert
(The number can be found in catalog of parts.)
Overview
1
2
Fig.454: Empty tape duct (example of SIPLACE X‑Series
shown)
1. Empty tape duct assembly
2. Empty tape duct insert
Fig.455: Empty tape duct insert (example of SIPLACE SX4
shown)
1. Empty tape duct
2. Screws fastening the empty tape duct
insert (left and right)
Removal
CAUTION
Do not dismantle the empty tape duct
Only the empty tape duct insert may be replaced. Do not dismantle the empty tape duct.
NOTICE
Inner empty tape duct insert
When using tape reels with deep pockets, you may need to remove the inner baffle. Refer
to the operating manual of your machine for details.
All screws are accessible in the installed state. The baffles can therefore be replaced inside
the machine.
Remove the two screws fastening the empty tape duct insert and remove these.
9 Component feeding
9.2 COT insert
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 325
Installation
Installation is performed by following the above instructions in the reverse order. Also observe
the following instructions:
Refit the empty tape duct insert on the empty tape duct if you are not using any compon-
ents >15mm.
Fig.456: Empty tape duct
CAUTION
The empty tape duct insert fits somewhat tightly in the empty tape duct
These can damage the coating in the empty tape duct, which can then lead to component
tapes getting jammed at the edges. This could then cause a head crash.
Never use sharp-edged objects to position the empty tape duct insert.
If necessary, use a wooden wedge or, as shown in the diagram, a brush with wooden
handle.
9 Component feeding
9.2 COT insert
326 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
9.2.11 Replacing the infeed control
Parts, equipment and tools
Fig.457: Feed control
1. Infeed control assembly SX4
[03082077-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Dismantle the nozzle changer over the feed control.
2.8.3 "Replacing the Nozzle Changer" [}40]
To gain better access, you may need to disconnect the COT insert and pull it slightly out of
the machine. Observe the instructions in section 9.2.2
"Installation Positions of COT Insert and
Manual Table (Table Positions)" [}313].
You can improve access by removing the upper section of the stationary camera, if present.
2.7 "Stationary component camera" [}33]
CAUTION
Component camera
The component camera mirror has sharp edges.
Take care not to damage the component camera.
Unplug all electrical connections to the insert control. You may want to mark the positions of
these connections to make clear assignment easier later on.
Remove the screws fastening the infeed control and remove the insert control from the
machine.
Installation
Follow the removal instructions in reverse order for installation.