00198829-01_SM_X-Series-S_Hxxxx_EN.pdf - 第63页
3 Power supply 3.4 Power supply and transformer modules Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 63 3.4.11 Replacing the Distribution and Fusing Assembly Parts, equipment and tools ● Distribution and fusing…

3 Power supply
3.4 Power supply and transformer modules
62 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
3.4.10 Replacing the main power cable
DANGER
For qualified electricians only - observe the instruction manual!
► This task may only be performed by a specially trained electrician.
Parts, equipment and tools
●
Cable: Mains power supply machine [00335210-xx]
●
Instruction manual for your machine
Overview
Fig.68: Mains connection cable
1. Mains connection cable
2. Strain relief
3. Electrical connections
Removal/installation
► Observe the relevant section of the instruction manual for your machine for removal and in-
stallation work.
DANGER
Checking for absence of voltage!
► Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4.3
"Checking For
Absence of Voltage" [}49].

3 Power supply
3.4 Power supply and transformer modules
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 63
3.4.11 Replacing the Distribution and Fusing Assembly
Parts, equipment and tools
●
Distribution and fusing board assembly [03118289‑xx]
Overview
Fig.69: Distribution and fusing board assembly
1. Distribution and fusing board assembly
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
► Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4.3
"Checking For
Absence of Voltage" [}49].
► Unplug all electrical connections to the board. You may like to mark their positions, to make
clear assignment easier later on.
3.4.11.1 "Distribution and fusing board assembly" [}64]
Fig.70: Fastening screws
► Remove the fastening screws on the
board and the ground conductor.
► Remove the board.
Installation
Follow the removal instructions in reverse order for installation.

3 Power supply
3.4 Power supply and transformer modules
64 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
3.4.11.1 Distribution and fusing board assembly
Fig.71: Distribution and fusing board assembly [03118289‑xx]
●
Micro fuse 5x20mmT 6.3A 250V (spare part) [03078843‑xx]
Each machine is supplied with a pack of 10 fuses.
CAUTION
Use only 6.3A fuses!
► If 10A fuses are present, replace them by 6.3A fuses.