00198829-01_SM_X-Series-S_Hxxxx_EN.pdf - 第40页

2 Basic Machine 2.8 Nozzle Changers and Reject Boxes 40 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 2.8.3 Replacing the Nozzle Changer NOTICE Row two, MTC2, WPC For more information about the row 2 nozzle chan…

100%1 / 382
2 Basic Machine
2.8 Nozzle Changers and Reject Boxes
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 39
Fig.33: Sensors for reject bin SIPLACE X-Series S with JTF
Fig.34: Sensors for reject bin SIPLACE X-Series S with JTF
2 Basic Machine
2.8 Nozzle Changers and Reject Boxes
40 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
2.8.3 Replacing the Nozzle Changer
NOTICE
Row two, MTC2, WPC
For more information about the row 2 nozzle changers and in combination with MTC2/
WPC, refer to the assembly instructions "NC row 2 - NC before MTC 2/
WPC" [DEEN:00197369‑xx].
Parts, equipment and tools
Select the relevant nozzle changers:
NC basic structure CPx/all assembly long [03147324–xx] (replaces [03103514‑xx]
[03070123‑xx])
NC CPx/all short [03147925‑xx] (replaces [03103649-xx] [03062463-xx])
Magazine holder assembly / NC P+P B series [03062453‑xx]
If required, NC shim plates [03021079-xx]
Depth measuring gauge (300mm) [03079617-xx]
Plastic plate
Overview
Fig.35: Nozzle changer with four nozzle magazines
1. Four nozzle magazines (4xxx/6xxx)
2. Four fixing screws
3. Four levers for removal of nozzle
magazines
4. Cover on the underside
The electronic and pneumatic compon-
ents are under the cover.
Fig.36: Overview of nozzle changers
1. Cover
2. Electrical connection
3. Compressed air connection
4. Valve
2 Basic Machine
2.8 Nozzle Changers and Reject Boxes
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 41
Removal
NOTICE
Short and long nozzle changer
The procedure for removal and installation is the same for the short and long nozzle
changer.
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}86]
Remove all magazines.
Remove the four fastening screws.
Unplug the nozzles changer from all electrical and pneumatic connections. You might like to
mark their positions to make clear assignment easier later on.
Take care not to lose the support plates. Remember their exact positions, as they will need to
be returned to these original positions, during assembly.
Carefully lift the nozzle changer out of the machine.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
If present: check the jumper on the nozzle changer.
2.8.6 "Jumpers on the Nozzle Changer" [}44]
Re-insert the support plates.
Check the mechanical installation height of the nozzle changer.
2.8.5 "Setting the Nozzle Changer Height" [}43]