4. Spindle Adjustment
4 - 78
(5) Related parameters
The parameters related to the coil changeover and the standard setting values used when using a
coil changeover motor are shown below.
No. Abbrev. Parameter name Description
Setting
range
Standard
value
SP037 SFNC5 Spindle function 5
F E D C B A 9 8 7 6 5 4 3 2 1 0
mkc2 mkch invm mtsl
bit Meaning when "0" is set Meaning when "1" is set Standard
0 mtsl1 Special motor constant setting invalid S pecial motor constant se tting
valid
1
2 mkch Coil switch function invalid Coil switch function valid 1
Set to "0003" when using coil changeover motor.
SP038 SFNC6 Spindle function 6
F E D C B A 9 8 7 6 5 4 3 2 1 0
lbsd hbsd lwid hwid
bit Meaning when "0" is set Meaning when "1" is set Standard
0
hwid H-coil wide-range constant output
invalid
H-coil wide-range constant output
valid
0
1
lwid L-coil wide-range constant output
invalid
L-coil wide-range constant output
valid
0
2 hbsd H-coil base slide invalid H-coil base slide valid 0
3 lbsd L-coil base slide invalid L-coil base slide valid 0
SP020 SDTS*
Speed detection
set value
Set the motor speed for which speed detection output is
performed.
The setting value is determined by Mitsubishi according to the
specifications of coil changeover motor.
0 to 32767
(r/min)
Depends
on the
motor to be
used.
SP047 SDTR* Speed detection
reset value
Set the reset hysteresis width for a speed detection set value
defined in SP020 (SDTS).
0 to 1000
(r/min)
Lathe: 300
Machining:
100
SP059 MKT
Winding
changeover base
shut-off timer
Set the base shut-off time for contactor switching at coil
changeover.
Note that the contactor may be damaged with burning if the
value of this parameter is too small.
50 to 10000
(ms)
150
SP060 MKT2
Current limit timer
after coil
changeover
Set the current limit time to be taken after completion of
contactor switching at winding changeover.
0 to 10000
(ms)
500
SP061 MKIL
Current limit value
after winding
changeover
Set the current limit value during a period defined in SP060
(MKT2) after completion of contactor switching at winding
changeover.
0 to 120
(%)
75

4. Spindle Adjustment
4 - 79
No. Abbrev. Parameter name Description
Setting
range
Standard
value
SP129
to
SP140
HI01
to
HI12
General-purpose input
selection
Set the general-purpose input signals IN1 to IN12 as to which
function they should have. To have the coil changeover function,
set "18" (L coil selection command) in one of those signals.
0 to 21 -
SP141
to
SP154
HO1e
to
HO1c
General-purpose
output selection
Set the general-purpose output signals OUT1 to OUT8 (open
emitter) or OUT1C to OUT6C (open collector) as to which
function they should have. Set "18" (L coil selected signal) in
one of those signals. Also, set "16" (changing coil) in another
signal as required.
0 to 23 -
SP257
to
SP320
Motor constant (H coil)
These parameters are valid only in the following two conditional
cases.
(a) SP034(SFNC2)/bit0=1 and SP034(SFNC2)/bit2=0
Set the motor constants for the special and non-coil
changeover motor not indicated in the explanation of SP040
(MTYP).
(b) SP034(SFNC2)/bit0=1 and SP034(SFNC2)/bit2=1
Set the H coil side motor constants of the coil changeover
motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to
FFFF
0000
SP321
to
SP384
Motor constant (L coil)
These parameters are valid only in the following case.
(a) SP034(SFNC2)/bit0=1 and SP034(SFNC2)/bit2=1
Set the L coil side motor constants of the coil changeover
motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to
FFFF
0000

4. Spindle Adjustment
4 - 80
(6) Coil changeover contactor (magnetic contact)
[1] Selection
The coil changeover contac tor is selected according to the applicable spindle drive unit's capacity
as shown below.
Spindle drive unit type Applicable contactor type Spindle drive unit type Applicable contactor type
MDS-A/B-SPA(H)-040 S-N10 MDS-A/B/C1-SPA(H)-150 S-N50
MDS-A/B-SPA(H)-075 S-N10 MDS-A/B/C1-SPA(H)-185 S-N65
MDS-A/B-SPA(H)-15 S-N10 MDS-A/B/C1-SPA(H)-220 S-N80
MDS-A/B-SPA(H)-22 S-N10 MDS-A/B/C1-SPA(H)-260 S-N80
MDS-A/B-SPA(H)-37 S-N18 MDS-A/B/C1-SPA(H)-300 S-N125
MDS-A/B/C1-SPA(H)-55 S-N20 MDS-B-SPA(H)-370 S-N150
MDS-A/B/C1-SPA(H)-75 S-N25 MDS-B-SPA(H)-450 S-N180
MDS-A/B/C1-SPA(H)-110 S-N35 MDS-B-SPA(H)-550 S-N300
[2] Outline
AC Class 3 rated working
current (A)
Support contact Dimensions (mm)
Name Model
200 to 220V 380 to 440V
Rated
conductivity
current (A)
Standard Special A B C
Open type
Non-
reversible
type
S-N10
S-N11
S-N12
S-N18
S-N20
S-N21
S-N25
S-N35
S-N50
S-N65
S-N80
S-N95
S-N125
S-N150
S-N180
S-N220
S-N300
S-N400
S-N600
S-N800
11
13
13
18
20
20
26
35
50
65
80
100
125
150
180
220
300
400
630
800
7
9
9
13
20
20
25
32
48
65
80
93
120
150
180
220
300
400
630
800
20
20
20
25
32
32
50
60
80
100
135
150
150
200
260
260
350
450
660(800)
800(1000)
1a
1a
1a1b
—
1a1b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
2a2b
1b
1b
2a
—
2a
—
—
—
—
—
4a4b
4a4b
4a4b
4a4b
4a4b
4a4b
4a4b
4a4b
4a4b
4a4b
43
43
53
43
63
63
75
75
88
88
100
100
100
120
138
138
163
163
290
290
78
78
78
79
81
81
89
89
106
106
124
124
150
160
204
204
243
243
310
310
78
78
78
81
81
81
91
91
106
106
127
127
136
145
174
174
195
195
234
234
S-N21 type