MDS-C1-SPA Series INSTRUCTION MANUALib1500152(eng)a.pdf - 第202页

Appendix 1. Cable and Connector Specifications A1 - 3 (3) Cable protection tube (noise countermeasure) If influence from noise is unavoidable, or further noi se resistance is required, selecting a flexible tube and runni…

100%1 / 234
Appendix 1. Cable and Connector Specifications
A1 - 2
Appendix 1-1 Selection of cable
Appendix 1-1-1 Cable wire and assembly
(1) Cable wire
The following shows the specifications and processing of the wire used in each cable. Manufacture
the cable using the following recommended wire or equivalent parts.
Wire characteristics Recommended
wire model
(Cannot be directly
ordered from
Mitsubishi
Electric Corp.)
Finished
outside
diameter
Sheath
material
No. of
pairs
Config-
uration
Conductor
resistance
Withstand
voltage
Insulation
resistance
Heat
resistant
temperature
Applica-
tion
UL20276 AWG28
10pair
6.1mm PVC 10
7
strands/
0.13mm
222/km
or less
AC350/ 1min
1M/km
or more
80°C
NC unit
communi-
cation cable
A14B2343 (Note 1) 7.2mm PVC 6
40
strands/
0.08mm
105/km
or less
AC500/ 1min
1500M/k
m or more
105°C
Detector
cable
2
(0.3 mm
2
)
60
strands/
0.08mm
63/km
or less
TS-91026 (Note 2) 11.6mm PVC
10
(0.2 mm
2
)
40
strands/
0.08mm
95/km
or less
AC750V/
1min
60M/km
or more
60°C
Detector
cable
(Cable length:
20m or more)
(Note 1) Junko Co. (Dealer: Toa Denki)
(Note 2) BANDO ELECTRIC WIRE (http: //www.bew.co.jp)
(2) Cable assembly
Assemble the cable as shown in the following drawing, with the cable shield wire securely
connected to the ground plate of the connector.
Ground plate
Shield
(external conductor)
Sheath
Shield
(external conductor)
Sheath
Core wire
Core wire
CAUTION
Do not mistake the connection when manufacturing the detector cable. Failure to
observe this could lead to faults, runaway or fires.
Appendix 1. Cable and Connector Specifications
A1 - 3
(3) Cable protection tube (noise countermeasure)
If influence from noise is unavoidable, or further noise resistance is required, selecting a flexible
tube and running the signal cable through this tube is effective. This is also an effective
countermeasure for preventing the cable sheath from being cut or becoming worn.
A cable clamp (MS3057) is not installed on the detector side, so be particularly careful of broken
wires in applications involving bending and vibration.
Connector
Supplier Tube
Drive unit side Installation screws Motor detector side
Nippon Flex
Control Corp.
FBA-4
(FePb wire braid sheath)
RBC-104 (straight)
RBC-204 (45°)
RBC-304 (90°)
G16
G16
G16
RCC-104-CA2022
DAIWA DENGYO
CO., LTD
Hi-flex
PT #17 (FePb sheath)
PSG-104 (straight)
PLG-17 (90°)
PS-17 (straight)
Screw diameter ø26.4
Screw diameter ø26.4
PF1/2
PDC20-17
Sankei Works
Purika Tube
PA-2 #17 (FePb sheath)
BC-17 (straight) Wire tube screws : 15 PDC20-17
(Note) None of the parts in this table can be ordered from Mitsubishi Electric Corp.
Appendix 1. Cable and Connector Specifications
A1 - 4
Appendix 1-2 Cable connection diagram
CAUTION
1. Do not mistake the connection when manufacturing the detector cable.
Failure to observe this could lead to faults, runaway or fires.
2. Do not connect anything to pins unless otherwise particularly specified when
manufacturing a cable. (Leave OPEN)
3. Contact Mitsubishi when manufacturing a cable longer than 30m.
4. Do not relay the cable which the shield cable is used in. Malfunctions may
occur due to noise from the motor drive wire, other cables or devices.
If the cable must be relayed, keep the peeled shield section as short as
possible (3cm or less), and separate the cable from the other drive wires and
cables. Mitsubishi will not be held liable for any problems that should occur
as a result of a relayed cable. The customer is responsible for providing
measures against noise.
(1) NC bus cable (Cable between spindle drive unit and power supply unit)
<SH21 cable connection diagram>
Drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
Drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
PE
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
PE
FG