MDS-C1-SPA Series INSTRUCTION MANUALib1500152(eng)a.pdf - 第62页

3. Setup 3 - 2 3-1 Initial setup 3-1-1 Setting the rotary switch Before turning on the power, the setti ngs of the spindle drive unit and power supply unit's rota ry switches must be confirme d and changed. Details …

100%1 / 234
3 - 1
3. Setup
3-1 Initial setup........................................................................................................................................ 3-2
3-1-1 Setting the rotary switch ............................................................................................................ 3-2
3-1-2 Transition of LED display after power is turned ON .................................................................. 3-3
3-2 Setting the initial parameters for the spindle drive unit..................................................................... 3-4
3-2-1 Parameter setting method ......................................................................................................... 3-4
3-2-2 List of spindle parameters.......................................................................................................... 3-6
3-3 Initial adjustment of the spindle PLG .............................................................................................. 3-26
3-3-1 Adjusting the PLG installation.................................................................................................. 3-26
3. Setup
3 - 2
3-1 Initial setup
3-1-1 Setting the rotary switch
Before turning on the power, the settings of the spindle drive unit and power supply unit's rotary
switches must be confirmed and changed.
Details
Setting the
rotary switch
Setting the MDS-C1- SPA Setting the MDS-C1-CV
0
Apply this setting when the power is
turned ON.
External emergency stop
invalid
1
2 Setting prohibited
3
4
Set when the parameter setting is
confirmed and changed.
External emergency stop valid
(Used CN23)
5
6
7
8
9
A Setting prohibited
B
C
D
E
F
Setting prohibited
POINT
Even if multiple spindle drive units are used for the same machine, set "0" for
the settings of all spindle drive units' rotary switches before the power is turned
ON.
Spindle drive unit
(MDS-C1-SPA)
Power supply unit
(MDS-C1-CV)
0
1 F
2 E
4 C
3 D
5 B
6 A
7 9
8
0
1 F
2 E
4 C
3 D
5 B
6 A
7 9
8
3. Setup
3 - 3
3-1-2 Transition of LED display after power is turned ON
The spindle drive unit and the power supply unit power have been turned ON, each unit will
automatically execute self-diagnosis and initial settings for operation, etc. The LEDs on the front of the
units will change as shown below according to the progression of these processes.
If an alarm occurs, the alarm No. will appear on the LEDs. Refer to "5-1-1 LED display when alarm or
warning occurs" for details on the alarm displays.
Initializing
Emergency stop state
(In selecting emergency stop input)
The LED will alternate between
F1
E7
not lit.
Repeats lighting and going out.
(1st axis in the display example)
NC power ON
Reset signal
ON state
Reset signal
ON
In selecting reset
signal input
Reset signal
OFF
Servo ON state
Servo OFF sate
D
r
i
ve un
i
ts
LED display
Power supply unit
LED display
Emergency stop
Ready OFF
Initializing
Initializing completed
Ready OFF state
In the middle of Ready ON
(charge completed)
Ready ON state
CAUTION
When starting the spindle system, be sure that the machine ready completion
input (Ready signal) is turned OFF, or that the emergency stop signal is
selected and input.