3. Setup 3 - 24 No. Abbr. Parameter name Details Setting range (Unit) Standard setting SP194 SE2R* Speed excessive deflection 2 detection range Set the speed detection width when the speed excessive deflection 2 alarm is…

100%1 / 234
3. Setup
3 - 23
No. Abbr. Parameter name Details
Setting
range
Standard
SP178 SMG*
Speed meter output full
scale adjustment
Adjust the speed meter full scale.
Adjust so that the fluctuations of the speed meter is at the
intended position when "1" is set in SP177(MADJ).
0 to 1000
(1/1000-fold
)
938
SP179 LMG*
Load meter output full
scale adjustment
Adjust the load meter full scale.
Adjust so that the fluctuations of the load meter is at the
intended position when "1" is set in SP177(MADJ).
0 to 1000
(1/1000-fold
)
938
SP180 Sgnb* Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 2500 0
SP181 HSgnb* Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 2500 0
SP182 VGHD Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 1000 0
SP183 VCGH Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 100 0
SP185 IQGH Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
1 to 1000 0
SP186 IDGH Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
1 to 1000 0
SP187 TQSLM Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 32767 60
SP188 TQgn* Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
-9999 to
9999
15
SP189 TQofs* Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
-999 to 999 0
SP190 TQflt* Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 2250 0
SP191 TQLMT* Fixed control constant
Set by Mitsubishi.
Set "0" unless otherwise designated.
0 to 150 0
SP192 FNC0
Function selection at
emergency stop
Set the state of alarm output and ready-ON output at the
emergency stop.
Setting
value
Alarm
output
Ready-ON output
0 Not
available
Turned OFF when the amount
of time set in SP055(SETM) has
passed after the motor had
stopped
1 Available Same as above
2 Not
available
Continued ON
3 Available Continued ON
(Note) When the ready-ON input signal is turned OFF, the
ready-ON signal turns OFF regardless of the settings
above.
0 to 1000 15
SP193 LMG2*
Load meter output
range changeover gain
This will be validated when "21" (load meter output range
changeover) is set in SP129(HI01) to SP140(HI12) and the
signal is turned ON. The load meter output voltage gain
equals to the value set here, and not to the one in
SP179(LMG).
When "0" is set, the gain has the same value as set in the
usual SP179(LMG).
0 to 32767
(1/1000-fold
)
0
Parameters having an abbreviation with "*" (MADJ*, etc.) are validated right after the settings are changed by the personal
computer, without turning the spindle drive unit's power ON and OFF.
3. Setup
3 - 24
No. Abbr. Parameter name Details
Setting
range
(Unit)
Standard
setting
SP194 SE2R*
Speed excessive
deflection 2 detection
range
Set the speed detection width when the speed excessive
deflection 2 alarm is output. The setting is as follows.
Detection width =
Speed command × current setting value/100 (r/min)
When the result of the expression above is smaller than
45r/min, the detection width is clamped at 45r/min. When
"0" is set, detection will not be carried out.
0 to 100
(%)
0
SP195 SE2T*
Speed excessive
deflection 2 detection
time
Set the duration required to detect the alarms indicated
above.
The speed excessive deflection 2 alarm is output when a
speed deflection larger than the speed detection width is
continued for more than the duration set here.
When "0" is set, detection will be carried out instantly.
0 to 3000
(ms)
0
SP196
to
SP224
Not used. Set "0". 0 0
SP225 OXKPH*
Position loop gain
magnification after
orientation completed
(H coil)
0 to 2560
(1/256-fold)
0
SP226 OXKPL*
Position loop gain
magnification after
orientation completed
(L coil)
0 to 2560
(1/256-fold)
0
SP227 OXVKP*
Speed loop proportional
gain magnification after
orientation completed
0 to 2560
(1/256-fold)
0
SP228 OXVKI*
Speed loop cumulative
gain magnification after
orientation completed
If gain changeover is valid (SP097: SPEC0/bitC=1) during
orientation control, set the magnification of each gain
changed to after orientation completed.
0 to 2560
(1/256-fold)
0
SP229 OXSFT*
Orientation virtual target
shift amount
Set the amount to shift the target position when orientation
virtual target position is valid (SP097: SPEC0/bitD=1).
0 to 2048
(360
deg/4096)
0
SP230
to
SP241
Not used. Set "0". 0 0
SP242 Vavx* Fixed control constant Set by Mitsubishi. Set "0" unless designated in particular. 0 to 32767 0
SP243 UTTM* Fixed control constant Set by Mitsubishi. Set "0" unless designated in particular. 0 to 5000 0
SP244 OPLP* Fixed control constant Set by Mitsubishi. Set "0" unless designated in particular. 0 to 4096 0
SP245 PGHS* Fixed control constant Set by Mitsubishi. Set "0" unless designated in particular. 0 to 1 0
SP246 Not used. Set "0". 0 0
SP247 Not used. Set "0". 0 0
SP248 FNC Fixed control constant Set by Mitsubishi. Set "0" unless designated in particular. 0 to 7 0
SP249 SMO* Speed meter speed
Set the motor rotation speed when the speed meter 10V is
output.
When set to "0", this parameter becomes the same as
SP017 (TSP).
0 to 32767
(r/min)
0
SP250 LMO* Load meter voltage
Set the voltage when the load meter 120% is output. When
set to "0", this becomes 10V.
0 to 10 (V) 0
SP251 Not used. Set "0". 0 0
SP252 Not used. Set "0". 0 0
Parameters having an abbreviation with "*" (SE2R*, etc.) are validated right after the settings are changed by the personal
computer, without turning the spindle drive unit's power ON and OFF.
3. Setup
3 - 25
No. Abbr. Parameter name Details
Setting range
(Unit)
Standard
setting
SP253 DA1NO*
D/A output channel 1
data number
Set the output data number for channel 1 of the D/A
output function.
When set to "0", the output is speedometer.
-32768 to
32767
0
SP254 DA2NO*
D/A output channel 2
data number
Set the output data number for channel 2 of the D/A
output function.
When set to "0", the output is speedometer.
-32768 to
32767
0
SP255 DA1MPY*
DA output channel 1
magnification
Set the data magnification for channel 1 of the D/A output
function.
The output magnification is the setting value divided by
256.
When set to "0", the output magnification becomes 1-fold,
in the same manner as when "256" is set.
-32768 to
32767
(1/256-fold)
0
SP256 DA2MPY*
DA output channel 2
magnification
Set the data magnification for channel 2 of the D/A output
function.
The output magnification is the setting value divided by
256.
When set to "0", the output magnification becomes 1-fold,
in the same manner as when "256" is set.
-32768 to
32767
(1/256-fold)
0
Parameters having an abbreviation with "*" (DA1NO *, etc.) are validated right after the settings are changed by the personal
computer, without turning the spindle drive unit's power ON and OFF.
No. Abbr. Parameter name Details
Setting range
(Unit)
Standard
setting
SP257
to
SP320
Motor constant
(H coil)
This parameter is valid only in the following two
conditional cases:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=0
Set the motor constants when using a special motor,
not described in the SP040 (MTYP) explanation and
when not using the coil changeover motor.
(b) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the H coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
SP321
to
SP384
Motor constant
(L coil)
This parameter is valid only in the following conditional
case:
(a) In case that SP034 (SFNC2)/bit0=1
and SP034 (SFNC2)/bit2=1
Set the motor constant of the L coil of the coil
changeover motor.
(Note) It is not allowed for the user to change the setting.
(HEX setting)
0000 to FFFF 0000
All motor constant parameters are validated with the spindle drive unit's power turned ON/OFF or with the alarm reset input turned
ON/OFF.