3. Setup 3 - 11 No. Abbr. Parameter name Details Setting rang e (Unit) Standard setting Set the spindle drive unit's capacity type. (HEX setting) Setting Unit capacity S etting Unit c apacity 0000 --- 0010 MDS-B-SPA…

3. Setup
3 - 10
No. Abbr. Parameter name Details
FEDCBA98765 4 3 2 10
dplg ospcl
noplg
nsno nosg psdir plgo
mago
enco
bit Meaning when set to 0 Meaning when set to 1 Standard
0 enco Encoder orientation invalid Encoder orientation valid 0
1 mago Magnetic sensor orientation invalid Magnetic sensor orientation valid 0
2 plgo PLG orientation invalid PLG orientation valid 0
3 0
4 0
5 0
SP037 SFNC5 Spindle function 5
6 0
7 psdir Position shift standard Position shift reverse direction 0
8 nosg
No-signal detection type
(Always monitoring)
No-signal detection valid only in
position loop or orientation-mode
0
9 nsno No-signal detection valid No-signal detection invalid 0
A noplg
Constant monitor of PLG-Z phase
no-signal invalid
Constant monitor of PLG-Z phase
no-signal valid
0
B 0
C 0
D ospcl
Orientation speed clamp
motor speed setting
Orientation speed clamp
spindle speed setting
0
E dplg This is set by Mitsubishi. Set to "0" unless particularly designated. 0
F 0
(Note 1) For bit0 to 2, do not set two bits or more to "1" at the same time.
(Note 2) Set 0 if there is no particular explanation for the bit.
FEDCBA98765 4 3 2 10
oplp lmx iqsv
dcsn lmnp vfbs orm Tdn plg2 alty
bit Meaning when set to 0 Meaning when set to 1 Standard
0alty
Deceleration stop during special
alarm invalid
Deceleration stop during special
alarm valid
0
1 0
2 0
3plg2
Semi-closed pulse signal output×2
invalid
Semi-closed pulse signal output×2
valid
0
4 Tdn This is used by Mitsubishi. Set to "0" unless particularly designated. 0
SP038 SFNC6 Spindle function 6
5 0
6 orm Orientation start memo invalid Orientation start memo valid 0
7 vfbs This is set by Mitsubishi. Set to "0" unless particularly designated.
8 0
9 0
A lmnp This is set by Mitsubishi. Set to "0" unless particularly designated.
Bdcsn
Dual cushion during acceleration/
deceleration valid
Dual cushion during acceleration/
deceleration invalid
0
C 0
DIqsv
Elmx
This is set by Mitsubishi. Set to "0" unless particularly designated
F oplp Open loop operation invalid Open loop operation valid 0
(Note) Set 0 if there is no particular explanation for the bit.

3. Setup
3 - 11
No. Abbr. Parameter name Details
Setting range
(Unit)
Standard
setting
Set the spindle drive unit's capacity type.
(HEX setting)
Setting Unit capacity
S
etting Unit capacity
0000 --- 0010 MDS-B-SPA-550
0001 MDS-B-SPA-075 0011 ---
0002 MDS-B-SPA -15 0012 ---
0003 MDS-B-SPA -22 0013 ---
0004 MDS-B-SPA -37 0014 ---
0005 MDS-C1-SPA-55 0015 ---
SP039 ATYP Drive unit type 0006 MDS-C1-SPA-75 0016 --- 0000 to FFFF 0000
0007 MDS-C1-SPA-110 0017 ---
0008 MDS-C1-SPA-150 0018 ---
0009 MDS-C1-SPA-185 0019 ---
000A MDS-C1-SPA-220 001A ---
000B MDS-C1-SPA-260 001B ---
000C MDS-C1-SPA-300 001C ---
000D MDS-B-SPA -370 001D ---
000E MDS-B-SPA -450 001E ---
000F MDS-B-SPA -04 001F ---
This parameter is valid when SP034 (SFNC2)/bit0 is set
to "0". (Old type of motor)
Set the appropriate motor number from the standard
motors listed below.
(HEX setting)
Setting Motor name
Maximum
speed
Corresponding
drive unit
0000 --- --- ---
0001 SJ-2.2A 10000 r/min MDS-B-SPA -22
0002 SJ-3.7A 10000 r/min MDS-B-SPA -37
0003 SJ-5.5A 8000 r/min MDS-C1-SPA-55
0004 SJ-7.5A 8000 r/min MDS-C1-SPA-75
0005 SJ-11A 6000 r/min MDS-C1-SPA-110
0006 SJ-15A 6000 r/min MDS-C1-SPA-150
0007 SJ-18.5A 6000 r/min MDS-C1-SPA-185
0008 SJ-22A 4500 r/min MDS-C1-SPA-220
0009 SJ-26A 4500 r/min MDS-C1-SPA-260
SP040 MTYP Motor type 000A SJ-30A 4500 r/min MDS-C1-SPA-300 0000 to FFFF 0000
000B --- --- ---
000C --- --- ---
000D --- --- ---
000E --- --- ---
000F --- --- ---
0010 --- --- ---
0011 SJ-N0.75A 10000 r/min MDS-B-SPA-075
0012 SJ-N1.5A 10000 r/min MDS-B-SPA-15
0013 SJ-N2.2A 10000 r/min MDS-B-SPA-22
0014 SJ-N3.7A 10000 r/min MDS-B-SPA-37
0015 SJ-N5.5A 8000 r/min MDS-C1-SPA-55
0016 SJ-N7.5A 8000 r/min MDS-C1-SPA-75
0017 --- --- ---
0018 --- --- ---
0019 --- --- ---
001A --- --- ---
001B SJ-J2.2A 10000 r/min MDS-B-SPA-22
001C SJ-J3.7A 10000 r/min MDS-B-SPA-37
001D SJ-J5.5A 8000 r/min MDS-C1-SPA-55
001E SJ-J7.5A 8000 r/min MDS-C1-SPA-75
001F --- --- ---

3. Setup
3 - 12
No. Abbr. Parameter name Details
Setting range
(Unit)
Standard
setting
F E D C B A 9 8 7 6 5 4 3 2 1 0
amp rtyp ptyp
bit Explanation
0
1
2
When the CN4 connector of the drive unit and the CN4 or CN9 connector
of the power supply are connected, setting below is necessary.
To validate the external emergency stop function, add 40h.
3
Setting 0x 1x 2x 3x 4x 5x 6x 7x 8x
4
x0 Not used CV-300
5
x1 CV-110 CR-10
6
x2 CV-220 CR-15
7
ptyp
x3 CR-22
x4 CV-37 CR-37
x5 CV-150
MDS-B-
CVE-450
MDS-B-
CVE-550
x6 CV-55 CV-260 CR-55
x7 CV-370
x8 CV-75 CR-75
x9 CV-185 CR-90
SP041 PTYP Power supply type
8
Set the regenerative resistor type when MDS-A-CR is used.
9 Setting Regenerative resistor model name
Resistance
value
Capacity
A0
MDS-C1-CV (Setting when using power supply regeneration)
B
rtyp
1
GZG200W260HMJ (Note)
26Ω
80W
2
GZG300W130HMJ×2
26Ω
150W
3
MR-RB30
13Ω
300W
4
MR-RB50
13Ω
500W
5
GZG200W200HMJ×3
6.7Ω
350W
6
GZG300W200HMJ×3
6.7Ω
500W
7
R-UNIT-1
30Ω
700W
8
R-UNIT-2
15Ω
700W
9
R-UNIT-3
15Ω
2100W
A~F
No setting
(Note) When MDS-B-SPA-370, 450 or 550 is used, set "0" even if power
regeneration type is applied.
C
D
E
F
amp
Always set to "0".
SP042 Not used. Set "0". 0 0
SP043 Not used. Set "0". 0 0
SP044 Not used. Set "0". 0 0
SP045 CSNT* Dual cushion timer
Set the cycle to add the increment values in the dual
cushion process.
When this setting value is increased, the dual cushion will
increase, and the changes in the speed during
acceleration/deceleration will become gradual.
0 to 1000 (ms) 0
Parameters having an abbreviation with "*" (CSNT*, etc.) are validated right after the settings are changed by the personal
computer, without turning the spindle drive unit's power ON and OFF.