Appendix 2. Compliance to EC Directives A2 - 3 (3) Pow er supply [1] Use the power supply and servo/spindle drive unit under an Overvoltage Category II as stipulated in IEC60664. [2] In case of Overvoltage Category III, …

100%1 / 234
Appendix 2. Compliance to EC Directives
A2 - 2
Appendix 2-1 Compliance to EC Directives
Appendix 2-1-1 European EC Directives
In the EU Community, the attachment of a CE mark (CE marking) is mandatory to indicate that the basic
safety conditions of the Machine Directives (issued Jan. 1995), EMC Directives (issued Jan. 1996) and
the Low-voltage Directives (issued Jan. 1997) are satisfied. The machines and devices in which the
servo and spindle drive are assembled are the targets for CE marking.
(1) Compliance to EMC Directives
The servo and spindle drive are components designed to be used in combination with a machine or
device. These are not directly targeted by the Directives, but a CE mark must be attached to
machines and devices in which these components are assembled. The next section "EMC
Installation Guidelines", which explains the unit installation and control panel manufacturing
method, etc., has been prepared to make compliance to the EMC Directives easier.
(2) Compliance to Low-voltage Directives
The MDS-C1-SPA Series units are targeted for the Low-voltage Directives. An excerpt of the
precautions given in this specification is given below. Please read this section thoroughly before
starting use.
A Self-Declaration Document has been prepared for the EMC Directives and Low-voltage
Directives. Contact Mitsubishi or your dealer when required.
Appendix 2-1-2 Cautions for EC Directive compliance
Use the Low-voltage Directive compatible parts for the servo/spindle drive and servo/spindle motor. In
addition to the items described in this instruction manual, observe the items described below.
(1) Configuration
Use a type B (AC/DC detectable type) breaker
Isolating
transformer
Circuit breaker
AC reactor
Electromagnetic
contactor
Drive unit
CB
MC
M
(2) Environment
Use the units under an Overvoltage Category II and Pollution Class of 2 or less environment as
stipulated in IEC60664.
These units do not provide protection against electric shock and fire sufficient for the requirements
of the Low-voltage Directive and relevant European standards by themselves, so provide additional
protection (refer to 5.2.4 and 7.1.6.1 of EN50178)
Drive unit Motor
During
operation
Storage
During
transportation
During
operation
Storage
During
transportation
Ambient
temperature
0°C to 55°C -15°C to 70°C -15°C to 70°C
Ambient
temperature
0°C to 40°C -15°C to 70°C -15°C to 70°C
Humidity
90%RH or
less
90%RH or
less
90%RH or less Humidity
80%RH or
less
90%RH or
less
90%RH or
less
Altitude
1000m or
less
1000m or
less
13000m or
less
Altitude
1000m or
less
1000m or
less
13000m or
less
Appendix 2. Compliance to EC Directives
A2 - 3
(3) Power supply
[1] Use the power supply and servo/spindle drive unit under an Overvoltage Category II as
stipulated in IEC60664.
[2] In case of Overvoltage Category III, connect the PE terminal of the units to the earthed-neutral
of the star-connection power supply system.
[3] Do not omit the circuit breaker and electromagnetic contactor.
(4) Earthing
[1] To prevent electric shocks, always connect the servo/spindle drive unit protective earth (PE)
terminal (terminal with
mark) to the protective earth (PE) on the control panel.
[2] When connecting the earthing wire to the protective earth (PE) terminal, do not tighten the
wire terminals together. Always connect one wire to one terminal.
PE terminal
PE terminal
[3] Select the earthing wire size in accordance with Table 1 of EN60204-1.
(5) Wiring
[1] Always use crimp terminals with insulation tubes so that the connected wire does not contact
the neighboring terminals.
Crim p termi nal
Insul ation tube
Wire
[2] Do not connect the wires directly.
[3] Select the size of the wires for input power supply to Power Supply unit in accordance with
Table 4 and 5 of EN60204-1.
Appendix 2. Compliance to EC Directives
A2 - 4
(6) Peripheral devices
[1] Use EN/IEC Standards compliant parts for the circuit breaker and contactor.
[2] Select circuit breaker with instantaneous trip function. (Trip within 30 second when over
current of 600%). Apply Annex C of EN60204-1 for sizing of the circuit breaker.
(7) Miscellaneous
[1] Refer to the next section "EMC Installation Guidelines" for methods on complying with the
EMC Directives.
[2] Ground the facility according to each country's requirements.
[3] The control circuit connector ({) is safely separated from the main circuit (
).
[4] Inspect the appearance before installing the unit. Carry out a performance inspection of the
final unit, and save the inspection records.
MC1
External emergency stop input
T
S
R
Contacto
r
No-fuse
breaker
Ground
: Main circuit
: Control circuit
CN23
CN4
L1
L2
L3
L11
TE3
TE1
CN9
CN12
L+
L-
U
V
W
CN6
CN5
TE1
PLG
Spindle drive unitPower supply unit
Spindle
motor
CN4
TE3
TE2
L+
L-
L11
L21
TE2
AC
reactor
Ground
Ground
L21
CN9A
CN8A
MC
Breake
r
CN11
CN10
ENC
Spindle side detector
S-analog speed command, pulse feedback
Speed
load meter, serial I/F
Digital speed command,
general-purpose
error output
Orientation position command,
General-purpose output
General purpose, general-purpose output
NC
PC
DIO
Meter
Personal compu te
r