MDS-C1-SPA Series INSTRUCTION MANUALib1500152(eng)a.pdf - 第69页
3. Setup 3 - 9 No. Abbr. Parameter name Details F E D C B A9876 5 4 3 2 10 l b s d h b s d l w i d h w i d bit Meaning when set to 0 Meaning when set to 1 Standard 0h w i d H-coil wide-range constant ou tput invalid H-co…

3. Setup
3 - 8
No. Abbr. Parameter name Details
F E D C B A 9 8 7 6 5 4 3 2 1 0
poff hzs ront
pycal
pychg
pyst pyoff sftk dflt
1a2m
bit Meaning when set to 0 Meaning when set to 1 Standard
0 1a2m 1 drive unit 2 motor function: Invalid 1 drive unit 2 motor function: Valid 0
1 dflt Default motor: Main Default motor: Sub 0
2 sftk Without SF-TK card With SF-TK card 0
3 0
4 0
5 0
SP033 SFNC1 Spindle function 1
6 pyoff This is set by Mitsubishi. Set to "0" unless particularly designated.
7 0
8 0
9 pycal (Conventional specifications)
High-speed rate deceleration
method valid for minimum excitation
rate
0
A 0
B 0
C ront Normal ready ON High-speed ready ON 0
D 0
Ehzs
Gate OFF by high-cycle zero speed
invalid
Gate OFF by high-cycle zero speed
valid
0
F poff
Contactor hold at NC power OFF
invalid
Contactor hold at NC power OFF
valid
0
(Note ) Set 0 if there is no particular explanation for the bit.
F E D C B A 9 8 7 6 5 4 3 2 1 0
mkc2 mkch
invm mtsl
bit Meaning when set to 0 Meaning when set to 1 Standard
0 mtsl Special motor constant invalid Special motor constant setting valid 0
1invm
A general-purpose motor FV control
invalid
A general-purpose motor FV control
valid
0
2 mkch Coil switch function invalid Coil switch function valid 0
3 mkc2 This is set by Mitsubishi. Set to "0" unless particularly designated. 0
4 0
5 0
SP034 SFNC2 Spindle function 2
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note ) Set 0 if there is no particular explanation for the bit.

3. Setup
3 - 9
No. Abbr. Parameter name Details
FEDCBA98765 4 3 2 10
lbsd hbsdlwidhwid
bit Meaning when set to 0 Meaning when set to 1 Standard
0hwid
H-coil wide-range constant output
invalid
H-coil wide-range constant output
valid
0
1lwid
L-coil wide-range constant output
invalid
L-coil wide-range constant output
valid
0
2 hbsd H-coil base slide invalid H-coil base slide valid 0
3 lbsd L-coil base slide invalid L-coil base slide valid 0
SP035 SFNC3 Spindle function 3
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.
FEDCBA98765 4 3 2 10
dslm
dssm
enc2 enc1
mag2 mag1
plg2 plg1
bit Meaning when set to 0 Meaning when set to 1 Standard
0 plg1 PLG of motor 1 valid PLG of motor 1 invalid 0
1 plg2 PLG of motor 2 valid PLG of motor 2 invalid 0
2 mag1 MAG of motor 1 valid MAG of motor 1 invalid 0
3 mag2 MAG of motor 2 valid MAG of motor 2 invalid 0
4 enc1 ENC of motor 1 valid ENC of motor 1 invalid 0
SP036 SFNC4 Spindle function 4
5 enc2 ENC of motor 2 valid ENC of motor 2 invalid 0
6 0
7 0
8 dssm Speedometer output valid Speedometer output invalid 0
9 dslm Load meter output valid Load meter output invalid 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.

3. Setup
3 - 10
No. Abbr. Parameter name Details
FEDCBA98765 4 3 2 10
dplg ospcl
noplg
nsno nosg psdir plgo
mago
enco
bit Meaning when set to 0 Meaning when set to 1 Standard
0 enco Encoder orientation invalid Encoder orientation valid 0
1 mago Magnetic sensor orientation invalid Magnetic sensor orientation valid 0
2 plgo PLG orientation invalid PLG orientation valid 0
3 0
4 0
5 0
SP037 SFNC5 Spindle function 5
6 0
7 psdir Position shift standard Position shift reverse direction 0
8 nosg
No-signal detection type
(Always monitoring)
No-signal detection valid only in
position loop or orientation-mode
0
9 nsno No-signal detection valid No-signal detection invalid 0
A noplg
Constant monitor of PLG-Z phase
no-signal invalid
Constant monitor of PLG-Z phase
no-signal valid
0
B 0
C 0
D ospcl
Orientation speed clamp
motor speed setting
Orientation speed clamp
spindle speed setting
0
E dplg This is set by Mitsubishi. Set to "0" unless particularly designated. 0
F 0
(Note 1) For bit0 to 2, do not set two bits or more to "1" at the same time.
(Note 2) Set 0 if there is no particular explanation for the bit.
FEDCBA98765 4 3 2 10
oplp lmx iqsv
dcsn lmnp vfbs orm Tdn plg2 alty
bit Meaning when set to 0 Meaning when set to 1 Standard
0alty
Deceleration stop during special
alarm invalid
Deceleration stop during special
alarm valid
0
1 0
2 0
3plg2
Semi-closed pulse signal output×2
invalid
Semi-closed pulse signal output×2
valid
0
4 Tdn This is used by Mitsubishi. Set to "0" unless particularly designated. 0
SP038 SFNC6 Spindle function 6
5 0
6 orm Orientation start memo invalid Orientation start memo valid 0
7 vfbs This is set by Mitsubishi. Set to "0" unless particularly designated.
8 0
9 0
A lmnp This is set by Mitsubishi. Set to "0" unless particularly designated.
Bdcsn
Dual cushion during acceleration/
deceleration valid
Dual cushion during acceleration/
deceleration invalid
0
C 0
DIqsv
Elmx
This is set by Mitsubishi. Set to "0" unless particularly designated
F oplp Open loop operation invalid Open loop operation valid 0
(Note) Set 0 if there is no particular explanation for the bit.