MDS-C1-SPA Series INSTRUCTION MANUALib1500152(eng)a.pdf - 第226页
Appendix 3. EMC Installation Guidelines A3 - 15 Outline dimension draw ings MX13030, MX13050 MX13100, MX13150 Model MX13030 MX13050 A 66 81 B 45 55 C 10.5 13 D 50 67 E 13 16 F 10 13 G 177 179 H M4 screw M6 screw I …

Appendix 3. EMC Installation Guidelines
A3 - 14
Example of using MX13 Series
This is a noise filter with the same dimensions as the MDS-D/DH series drive unit depth (200mm) and
height (380mm).
This unit can be laid out easily in the device by arraigning it in a row with the servo unit.
As with the servo unit, the terminals are arranged on the front enabling ideal wire lead-out.
Refer to the following figure for details.
Noise filter (MX13 Series)
Servo unit
200
380
Wire to 3-phase power supply
Noise filter input terminal
Noise filter output terminal
Servo input terminal
Wire from noise filter to servo
Example of noise terminal voltage attenuation
Output derating
Noise terminal voltage
[
dBuV
]
EMI data for independent control panel
(with six-axis servo unit mounted)
Noise terminal voltage
EMI data for control panel + noise filter
(MX13030)
[dBuV]
A
mbient temperature Ta (°C)
Current (%)

Appendix 3. EMC Installation Guidelines
A3 - 15
Outline dimension drawings
MX13030, MX13050
MX13100, MX13150
Model MX13030 MX13050
A 66 81
B 45 55
C 10.5 13
D 50 67
E 13 16
F 10 13
G 177 179
H M4 screw M6 screw
I 70 85
J M4 screw M6 screw
K 195 200
(Installation hole)
[Unit: mm]
Model MX13100 MX13150
A 130 165
B 90 110
C 20 27.5
D 115 150.5
E 37.5 57.5
F 18 23
G 174 176
H M6 screw M8 screw
I 21 27
J 37.5 56.5
K 115 149.5
L 276 284
(Installation hole)
(Installation hole)
[Unit: mm]

Appendix 3. EMC Installation Guidelines
A3 - 16
Appendix 3-6-4 Surge protector
Insert a surge protector in the power input section to prevent damage to the control panel or power
supply unit, etc. caused by the surge (lightning or sparks, etc.) applied on the AC power line.
Use a surge protector that satisfies the following electrical specifications.
(1) 200V Surge protector
200V R・A・V BYZ Series
Part name
Circuit
voltage
50/60Hz
Maximum
tolerable
circuit voltag
e
Clamp
voltage
Surge
withstand
level
8/20 µS
Surge
withstand
voltage
1.2/50 µS
Electrostatic
capacity
Service
temperature
RAV-781BYZ-2 3AC 250V 300V 783V±10% 2500A 20kV 75pF -20 to 70°C
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and specifications.
2
8
.
5
±
1
5
.
5
±
1
1
1
±
1
2
8
±
1
2
0
0
±
3
0
0
41±1
4
.
5
±
0
.
5
Outline dimension drawings
Circuit diagram
[Unit: mm]
(1) Black
UL-1015 A WG16
(2) Black
(3) Black
41±1
28±1
200±
30
0
5.5±1
28.5±1
11±1
4.5±0.5
200V R・A・V BXZ Series
Part name
Circuit
voltage
50/60Hz
Maximum
tolerable
circuit voltag
e
Clamp
voltage
Surge
withstand
level
8/20 µS
Surge
withstand
voltage
1.2/50 µS
Electrostatic
capacity
Service
temperature
RAV-781BXZ-4 3AC 250V 300V 1700V±10% 2500A 2kV 75pF -20 to 70°C
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and specifications.
2
8
.
5
±
1
5
.
5
±
1
1
1
±
1
2
8
±
1
2
0
0
±
3
0
0
41±1
4
.
5
±
0
.
5
U
Outline dimension drawings Circuit diagram
[Unit: mm]
(1) Black (2) Black (3) Black
UL-1015 A WG16
Green
41±1
28±1
200±
30
0
5.5±1
28.5±1
11±1
4.5±0.5