LCX_UserManual_en_08_1.pdf - 第236页
Remote control commands R&S ® LCX Series 236 User Manual 1 179.2260.02 ─ 08 SYST em:BEEPer:W ARNing:ST A T e <En-/Disable warning beep> Activates the R&S LCX to create an acoustic signal on errors and warni…

Remote control commands
R&S
®
LCX Series
235User Manual 1179.2260.02 ─ 08
*************************************************
// Set the USB interface protocol:
INTerfaces:USB:CLASs "TMC"
INTerfaces:USB:CLASs.................................................................................................. 235
SYSTem:BEEPer:WARNing:STATe.................................................................................. 236
SYSTem:BEEPer:WARNing[:IMMediate].......................................................................... 236
SYSTem:BEEPer[:COMPlete]:STATe............................................................................... 236
SYSTem:BEEPer[:COMPlete][:IMMediate]........................................................................236
SYSTem:COMMunicate:LAN:ADDRess............................................................................237
SYSTem:COMMunicate:LAN:APPLy................................................................................ 237
SYSTem:COMMunicate:LAN:DGATeway..........................................................................237
SYSTem:COMMunicate:LAN:DHCP.................................................................................237
SYSTem:COMMunicate:LAN:DISCard..............................................................................237
SYSTem:COMMunicate:LAN:EDITed?..............................................................................237
SYSTem:COMMunicate:LAN:HOSTname.........................................................................238
SYSTem:COMMunicate:LAN:MAC?.................................................................................238
SYSTem:COMMunicate:LAN:RESet.................................................................................238
SYSTem:COMMunicate:LAN:SMASk............................................................................... 238
SYSTem:COMMunicate:NETWork:VNC:PORT..................................................................238
SYSTem:COMMunicate:NETWork:VNC[:STATe]............................................................... 239
SYSTem:COMMunicate:NETWork:VNC:PORT..................................................................239
SYSTem:COMMunicate:NETWork:VNC[:STATe]............................................................... 239
SYSTem:DATE.............................................................................................................. 239
SYSTem:HW:VERSion?..................................................................................................240
SYSTem:KEY:BRIGhtness.............................................................................................. 240
SYSTem:LOCal..............................................................................................................240
SYSTem:REMote........................................................................................................... 240
SYSTem:RESTart...........................................................................................................240
SYSTem:RWLock...........................................................................................................241
SYSTem:SETTing:DEFault:SAVE.................................................................................... 241
SYSTem:TIME...............................................................................................................241
SYSTem:UPTime?......................................................................................................... 241
INTerfaces:USB:CLASs <USB class>
Selects the USB communication class.
Parameters:
<USB class> CDC | TMC
CDC
Uses the virtual communication port protocol, that enables you
to emulate serial ports over USB.
TMC
Uses the protocol for communication with USB devices.
Example: See Example "Network communication settings" on page 234.
Manual operation: See "USB Class" on page 166
SYSTem subsystem

Remote control commands
R&S
®
LCX Series
236User Manual 1179.2260.02 ─ 08
SYSTem:BEEPer:WARNing:STATe <En-/Disable warning beep>
Activates the R&S LCX to create an acoustic signal on errors and warnings.
The query returns the current state.
Parameters:
<En-/Disable warning
beep>
1 | 0 | ON | OFF
*RST: 1|ON
Example: See Example "General instrument settings" on page 232.
Manual operation: See "Error Beep" on page 135
SYSTem:BEEPer:WARNing[:IMMediate]
Activates that the R&S LCX issues a beep on error or warning immediately.
Parameters:
<state> 1 | 0 | ON | OFF
*RST: ON | 1
Example: See Example "General instrument settings" on page 232.
Usage: Event
Manual operation: See "Error Beep" on page 135
SYSTem:BEEPer[:COMPlete]:STATe <En-/Disable operation complete beep>
Activates the R&S LCX to create an acoustic signal on a completed operation.
The query returns the current state.
Parameters:
<En-/Disable
operation complete
beep>
1 | 0 | ON | OFF
*RST: ON | 1
Example: See Example "General instrument settings" on page 232.
Manual operation: See "Error Beep" on page 135
SYSTem:BEEPer[:COMPlete][:IMMediate]
Activates that the R&S LCX issues a beep after operation complete immediately.
The query returns the current state.
Parameters:
<boolean> 1 | 0 | ON | OFF
*RST: ON | 1
Example: See Example "General instrument settings" on page 232.
Usage: Event
SYSTem subsystem

Remote control commands
R&S
®
LCX Series
237User Manual 1179.2260.02 ─ 08
Manual operation: See "Error Beep" on page 135
SYSTem:COMMunicate:LAN:ADDRess <Ip address>
Sets the IP address.
Parameters:
<Ip address> Range: 0.0.0.0. to ff.ff.ff.ff
Example: See Example "Network communication settings" on page 234.
Manual operation: See "IP Address" on page 162
SYSTem:COMMunicate:LAN:APPLy
Assigns and confirms the settings.
Example:
See Example "Network communication settings" on page 234.
Usage: Event
SYSTem:COMMunicate:LAN:DGATeway <Gateway>
Sets the IP address of the default gateway.
Parameters:
<Gateway> Range: 0.0.0.0. to ff.ff.ff.ff
Example: See Example "Network communication settings" on page 234.
Manual operation: See "Gateway" on page 163
SYSTem:COMMunicate:LAN:DHCP <En-/Disable DHCP>
Parameters:
<En-/Disable DHCP> ON | OFF | 1 | 0
*RST: OFF | 0
Example: See Example "Network communication settings" on page 234.
Manual operation: See "DCHP & Auto-IP" on page 162
SYSTem:COMMunicate:LAN:DISCard
Removes the LAN configuration.
Usage:
Event
SYSTem:COMMunicate:LAN:EDITed?
Usage:
Query only
SYSTem subsystem