Getting started R&S ® LCX Series 41 User Manual 1 179.2260.02 ─ 08 Indicator Description GPIB/IEE-488 The IEE-488 bus interface (GPIB) connection is established. See Section 10.4, "Connecting the R&S LCX for…

Getting started
R&S
®
LCX Series
40User Manual 1179.2260.02 ─ 08
The color of the symbols indicates the status of, e.g. a function, connection or a proc-
ess:
●
white - enabled, or running
●
gray - disabled
●
red - faulty
●
yellow - denotes a specific status
Table 4-7: Instrument status bar
Indicator Description
Touchscreen
Indicates that the touchscreen is locked.
See Section 9.3, "User button", on page 127
Virtual Network Computing
White indicates that the VNC service is enabled for remote access over
LAN.
See "Remote operation (VNC)" on page 150.
File Transfer Protocol
White indicates that the remote access to the file system over LAN is
enabled.
See "Remote file access (FTP)" on page 151.
(Remote control with SCPI
commands)
Indicates the status when working with remote control commands:
●
single white flash: SCPI command received successfully
●
red: a remote control error has occurred, entered in the SCPI error
queue
●
gray: no SCPI communication
Continuous measurement
mode
Indicates the status of the continuous mode:
●
white: continuous measurement is running
●
gray: continuous measurement mode disabled
See Section 8.1, "Measurement mode", on page 70
Triggered measurement mode
Indicates the trigger status:
●
white: measurement is triggered and running
For fast measurements, the icon lights up only briefly.
●
gray: waiting for the next trigger event and triggered disabled
●
yellow: waiting for a trigger event during a trigger delay
Logging
Indicates the logging state:
●
white: data logging is running
●
red: a logging error has occurred
●
gray: logging is disabled
See Section 8.8.3, "Logging", on page 101
USB host interface
White indicates that a connected USB memory device is in use.
See Section 4.1.8, "Connecting USB devices", on page 25.
USB device interface The USB remote control connection is established.
See "Establishing a USB remote control connection" on page 168.
LAN interface
The R&S LCX is connected to LAN.
See Section 4.1.7, "Connecting to LAN", on page 24.
Instrument control

Getting started
R&S
®
LCX Series
41User Manual 1179.2260.02 ─ 08
Indicator Description
GPIB/IEE-488 The IEE-488 bus interface (GPIB) connection is established.
See Section 10.4, "Connecting the R&S LCX for remote access",
on page 167.
Time
Indicates the time set on the instrument.
See Section 9.6, "Date & time", on page 132.
Measurement status bar
The measurement status bar provides information on certain measurement modes,
functions and states. When activated, indicators displayed in white color represent the
corresponding functions.
For information on the measurement modes and functions, see "About measurement
parameters" on page 76.
Table 4-8: Measurement status bar
Indicator Description
Measurement mode
Measurement speed
Indicates the set measurement speed:
●
superfast, 4 ms
●
fast, 15 ms
●
medium, 100 ms
●
slow, 500 ms
See "Speed" on page 80
"O", "S", "L"
Indicates the state of open, short, and load correction.
●
white: full correction enabled
●
blue: spot correction enabled
●
yellow: questionable spot correction
●
black: uncorrected
●
gray: correction disabled
The dot "˙" at the top right indicates spot correction.
See Section 8.6.2, "Open/short/load correction settings", on page 82
"LowZ"
The low impedance measurement mode is set.
See "Source Impedance" on page 80
Instrument control

Getting started
R&S
®
LCX Series
42User Manual 1179.2260.02 ─ 08
Indicator Description
"BIAS"
Indicates an activated bias:
●
"VBIAS": voltage bias, provided for capacitance measurements
●
"IBIAS": current bias, provided for inductance measurements
●
"eVBIAS": external voltage bias, for capacitance measurements
If disabled, the icons are grayed out.
See Section 8.4.1, "Test signal settings", on page 74
"Cable Length"
White indicates that the cable length is set. The R&S LCX displays the
set value (currently only 1 m applicable).
See "Cable Length" on page 80
Settings softkey
The (settings) softkey opens the measurement dialog for setting additional basic
measurement parameters.
Configuration preset softkeys
The (preset configuration) softkeys recall previously assigned measurement con-
figurations, defined for dedicated measurements. You can assign up to three predefina-
ble configuration presets.
How to: see Section 8.7.2, "Using the configuration preset function", on page 92
Signal parameters
Figure 4-8: Measurement signal parameters
Each softkey opens an on-screen keypad for setting the signal parameters directly.
Alternatively, you can use the corresponding settings keys at the front panel.
Test signal monitor
Figure 4-9: Test signal monitor of L,C, R measurements
Instrument control